Agilent (HP) E5515C

8960 Series 10 (E5515C) Wireless Communications Test Set


WEBHP_E5515C.jpg

Standard Calibration:

$899.00

z540 Calibration:

$1,429.00

Add Agilent (HP) E5515C to Quote
Add Agilent (HP) E5515C to Wish List
Model Details
The E5515C hardware platform for the 8960 Series 10 wireless communication test set offers mobile manufacturers immediate competitive advantages. Developed for high-volume, automated mobile phone manufacturing test, the proven 8960 wireless communications test set offers speed, accuracy, repeatability, multi-format capability, ease of programming, and format-flexible architecture. For the mobile manufacturer, this translates into lower test costs and higher production output to help meet customer demand for phones now and into the future.

Recent additions to the 8960 extend its use into the design and development of wireless devices. Use the new lab applications to verify and troubleshoot your wireless designs by using powerful protocol logging features in addition to the extensive parametric testing.

Features:
  • Can be configured for W-CDMA, cdma2000,1xEV-DO, IS-95, GSM, GPRS, EGPRS, TIA/EIA-136, and AMPS mobile phone testing
  • Multi-format capability
  • Ease of programming
  • Format-flexible architecture


Key Capabilities
  • Fast device calibration across level and frequency
    simultaneously
  • Test HSDPA EVM as defined in 3GPP TS34.121
  • Test HSDPA throughput of MAC-hs at 3.6 Mb/s
  • Switch between all HSDPA sub-test conditions while
    on an active connection
  • Test all UMTS technologies with one connection
    maintained throughout
  • Graphical analysis of HS-DPCCH
  • Test all frequency bands I through VI, VIII, and IX


New Key Features
  • Fast device tune measurement
  • HSDPA waveform quality, code domain, and IQ tuning
    measurements
  • HSDPA user-defined DL configuration
  • HSDPA hard handovers between frequencies
  • Handovers of many HSDPA parameters
  • Handovers from HSDPA to GSM and from HSDPA to
    W-CDMA
  • Additional phase discontinuity measurement patterns

  • Frequency bands VIII and IX, and modified channel
    structure for frequency bands III and IV

Calibration Pricing

Std. Cal Price: $899.00
z540 Cal Price: $1,429.00
Post a Review, Comment, or Question
Name: Review/Comments: (Text only, no HTML)
E-mail:
(will not be published)
Rating:
Accessories
5040-6973 FRONT COVER, 8960
5968-7873E CONFIG GUIDE
5971-5127 Documenation guide
5971-5906 PROG:GETTING STARTED GUIDE
5971-5963 GPIB Command Syntax Rev A.01/C.01
5971-5984 GPIB Command Syntax Rev A.02/C.02
5971-5995 GPIB Command Syntax Rev A.03/C.03
8121-0510 CABLE, LAN X-OVER(installed on rear
E5515-10007 Sim Card - UMTS Test USIM Card
Options
001 Factory upgrade to latest HW, 1 year warranty and TA of choice
002 Second RF Source(Required for all GSM, GPRS, and EGPRS E5515C-002 applications.)
003 Flexible CDMA base station emulator (Required for all cdma2000/ IS-95/AMPS, W-CDMA, and 1xEV-DO applications.
004 Digital Bus (Enables fading in cdma2000, 1xEV-DO, and W-CDMA LAs. Requires E5515C-003.
0B0 Do not include manuals
185 Add Fast Switch and Improve Speed
285 Add Fast Switch and Improve speed
370 E6571A Wireless Test Manager run-time license. Requires a PC with a parallel port.
371 E6571C wireless test manager run-time license
500 RTI Upgrade
501 Add Fast Tune Capable Step Attenuator
502 Add option 002, replaced by Opt. 622
503 Add Option 003
504 Add Option 004 Digital Bus (Enables fading in cdma2000, 1xEV-DO, and W-CDMA LAs. Requires E5515C-003.
505 ADC Upgrade. Add Functionality Capabilities to early versions
507 DSP Upgrade
508 Protocol Upgrade 3
509 Extended Frequency Capability
513 Add Enhance CDMA Capability
515 5.8 Rear Panel Upgrade
587 Microprocessor Upgrade for early units
589 High Data Rate/ High Performance H/W
607 DSP Upgrade 3
612 Add Option 002 Second RF Source(Required for all GSM, GPRS, and EGPRS E5515C-002 applications.)
613 LSS Digital Upgrade 3
622 Add option 002 and Fast Edge Capability
665 EGPRS HW UPGRADE KIT E5515C (AGI)
687 Add Host Processor Upgrade for E1987A Compatability
765 Add Capabilty for WCDMA for early versions
963 old HW versions to HW 5.8
ABA U.S. Quick Users Guide (English localization)
ATP02 ATP lead-time item for E5515C NPI applications
AUE Upgrade service, 2 yr. ext
AUS Agilent Upgrade service,2yr
AX3 Front Handle Kit
AX4 Rack Mount Flange Kit
AX5 Flange and Handle Kit
B8A Operation verification at installation
CU508 Protocol
CU515 Rear Panel
CU607 DSP
CU613 Digital LSS
CU687 Host
DEF Upgrade service deferral
E16 225MHz universal counter - 10 digits (53181A)
E1960A GSM Mobile Test Application
E1961A AMPS/136 mobile test application.
E1962B CDMA2000 /IS-95/ AMPS Mobile Test Appication
E1962B-401 cdma2000 Rel A New Channels Mobile Test Application for F-BCCH, F-cch and R-EACH
E1962B-402 cdma2000 Advanced AMPS Measurements
E1962B-403 cdma2000 authentication Mobile Test Application
E1962B-405 cdma2000®/IS-95/AMPSDigital bus (fading)
E1962B-406 cdma2000 Multi-unit synchronization
E1962B-407 cmda2000 Protocol logging
E1962B-409 cdma2000 SMS
E1963A W-CDMA Mobile Test Application
E1963A-401 W-CDMA video phone test Mobile Test Application
E1963A-402 W-CDMA video loopback
E1963A-403 HSDPA FDD, 7.2 Mbps RB; H/W CU/513
E1963A-405 HSDPA 14.4Mbps TM, must already have an E1963A-403 license
E1963A-408 W-CDMA enhanced audio
E1963A-409 W-CDMA Advanced SMS
E1963A-413 HSUPA FDD / RB Test Mode, Dec. requires 403
E1963A-423 HSPA+TEST MODES requires E1963A-403, -405 & -413 license
E1964A GPRS Mobile Test Application
E1966A 1xEV-DO Mobile Test Application - A.06 need 4.8(285/687)
E1966A-102 Rel. A ETAP&FTM and Rel. B MCTAP signal carrier need 5.0 / 4.8+513. No PS Data;
E1966A-103 1xEV-DO Rel B Multi Carrier (prerequisite 102 and 406)
E1966A-405 1xEV-DO Digital bus (fading)
E1966A-406 1xEV-DO Multi-unit sync
E1966A-407 1xEV-DO Protocol logging
E1968A-101 GSM Mobile Test Application
E1968A-102 GPRS Mobile Test Application
E1968A-103 EGPRS Mobile Test Application
E1968A-201 GSM and GPRS Mobile Test Application
E1968A-202 GSM/GPRS/EGPRS Mobile Test Application
E1968A-408 GSM/GPRS Enhanced Audio
E1968A-409 GSM/GPRS Adv. SMS
E1968A-410 PAvT Mobile Test Application
E1968A-417 8PSK Distortion calibration
E1968A-419 Mobile Calculated BER
E1968A-430 Class 34
E1976A-102 1xEV-DO Rel A and B FTM
E1985A GSM, AMPS, IS-136 dual band, GPRS, W-CDMA Mobile Test Application
E1985B GSM, GPRS, EGPRS, IS-136 (800 MHz and 1900 MHz bands), AMPS, and W-CDMA Mobile Test Application
E1985C GSM, GPRS, EGPRS, cdma2000, IS-95, and AMPS Mobile Test Application
E1985D Combines E1985B, C and E Mobile Test Applications
E1985E cdma2000, IS-95, 1xEV-DO, and AMPS Mobile Test Application
E1987A Fast Switching Test Application for GSM, GPRS, EGPRS, cdma2000, IS-95, IS-136, W-CDMA, 1xEV-DO, and 1xEV-DO Release A
E1990A CDMA 2000
E1991A 8960 test application suite: E1960A (GSM), E1961A (AMPS/136), E1962B (cdma2000), E1963A (W-CDMA), E1964A (GPRS), and E1985A (fast switching)
E1991B 8960 test application suite. Includes TAs for GSM, GPRS, EGPRS (E1968A-201), AMPS & IS-136 TDMA (E1961A), cdma2000, IS-95, AMPS (E1962B), 1xEV-DO (E1966A), W-CDMA (E1963A) and fast switching (E1987A).
E1992A GSM/GPRS
E1993A 8960 UMTS test application suite. Includes TAs for GSM, GPRS, EGPRS, AMPS, W-CDMA and fast switching. Contains E1968A-202, E1963A, and E1987A TAs. (
E1996A 8960 cdma2000/1xEV-DO test application suite. Includes TAs for cdma2000, IS-95, 1xEV-DO, AMPS and fast switching. Contains E1962B, E1966A, and E1987
E1999A-201 Fast device tune measurement. Enables fast device tune measurement in E1962B, E1963A, E1966A, and E1987A TAs. (Requires E1962B, E1963A, or E1966A TA
E6569C Wireless Test Manager Suite
E6701D GSM/GPRS Lab App rev.D
E6701E GSM/GPRS Lab App rev.E
E6701T GSM / GPRS Lab Application
E6702B Special cdma2000 lab application
E6702T Special cdma2000 lab application
E6703C WCDMA LA rev C
E6703D WCDMA LA rev D
E6703T Special High Data Rate W-CDMA/HSDPA Lab Application
E6704A EGPRS LA
E6706A 1xEV-DO lab application
E6706T Special high data rate 1xEV-DO lab application
E6716T Special cdma2000/1xEV-DO lab application suite
E6717C Includes E6701F, E6704A , E6703E, E6785E
E6717T Special high data rate UMTS lab application suite
E6719T Special high data rate lab application suite
E6720A-17 UMTS Lab Application Annual Contract
E6785T Special high data rate fast switching lab application
H03 E-GPRS capable hardware
H07 Special option to get HSDPA HW capability on new E5515C (HW 5.1)
H08 Add special high data rate/high performance HW to E5515C
H09 Special Extended Frequency Range Hardware
H13 Special Application Revision Required
H16 gpsOne calibration
N5970A UMTS Interactive Functional Test Software
R-51B-001-3C 1 year Return-to-Agilent warranty extended to 3 years
R2C Revision to Current - CPL exclude
R45 Hardware revision 4.5
R48 Hardware revision 4.8
R50 Hardware revision 5.0
R51 Hardware revision 5.1
R55 Hardware revision 5.5
RMKT Agilent Refurbished Product (Do Not Use - Certiprime Option)
UK6 Commercial calibration with test results data
W30 3 Years Return for Repair Service

Ask a Question About This Unit

* = Required Information

Question About: Agilent (HP) E5515C

Contact Information

Company *
First Name *
Last Name *
eMail Address * [Privacy Policy]
Phone No.
Bill To Address Ship To Address (Same as Bill To)
ATTN:
Address 1
Address 2
Address 3
City
State
Other State/Province
Zip/Postal Code *
Country
ATTN:
Address 1
Address 2
Address 3
City
State
Other State/Province
Zip/Postal Code
Country

Question/Requests


Click here for BBB Business Review