Keysight (Agilent) E8363B

PNA- Vector Network Analyzer, 10 MHz - 40 GHz
Contact us for pricing and availability.
Description
General-purpose network analysis with optional software and/or hardware to customize for your application - such as multiport, pulsed-RF, etc.

Discuss calibration, applications, programming topics: Network Analyzer Discussion Forum

Support: PNA Series Service & Support

Features:
  • 110 dB of dynamic range <0.006 dB trace noise
  • <26 usec/point measurement speed, 32 channels, 16,001 points
  • TRL/LRM calibration, on-wafer, in-fixture, waveguide, and antenna measurements
  • Mixer conversion loss, return loss, isolation, and absolute group delay
  • Amplifier gain compression, harmonic, IMD, and pulsed-RF
List of Options
010 Time Domain
014 Configurable Test Set Option (front panel access loops between source output and coupler input)
016 Add Reciever Attenuators (35 dB in 5 dB steps)
022 Extended Memory 512MB
080 Frequency- Offset ( for use with mixers, converters and amplifiers)
081 Reference Channel Switch (Adds internal switch to R1 Path)
083 Frequency Converter Measurement Application S/W
1A7 ISO 17025 Compliant Calibration
1CM Rackmount Kit
1CP Rackmount and Handle Kit
550 4 Port Measurement Application (Enables full 4-port error correction and differential measurements on 2 Port N/A.)
700 Standard test set
720 Extended Memory 512 MB
830 Option Bundle Package of UNL, 014,016,080,081,and H11
831 Option Bundle Package of UNL, 014,080,081,and H11
903 120V POWER CORD
A6J ANSI Z540 compliant calibration with test data
AB1 Korea Quick Users Guide (Korean localization)
AB2 China Quick Users Guide (Chinese localization)
ABA U.S. Quick Users Guide (English localization)
ABD Germany Quick Users Guide (German localization)
ABE Spain Quick Users Guide (Spanish localization)
ABF France Quick Users Guide (French localization)
ABJ Japan Quick Users Guide (Japanese localization)
ABZ Italy Quick Users Guide (Italian localization)
H08 Pulsed-RF measurement capability
H11 IF Access (for antenna,point in pulse,pulse profile and broadband MM wave measurements.)
H85 High Power Option w/o Bias Tees. (allows RF Amplifiers between RF Source and Coupler Input)
P02 2 Port
P04 4 Port
R-51B-001-3C 1 year Return-to-Agilent warranty extended to 3 years
RMKT Agilent Refurbished Product (Do Not Use - Certiprime Option)
UK6 Commercial calibration with test results data
UNL High Power Measurement w/ Bias tees Configuration (Allows Ext. Amplifiers between RF Source and Coupler Input)
Z5623A-H81 2 GHz - 20 GHz Uni Directional Pulse Test Set
Z5623A-H83 2 GHz - 20 GHz Dual Directional Pulse Test Set.
Z5623A-H84 2GHz-40 GHz Dual Directional Pulse Test Set
Z5623A-H85 1GHz-40 GHz Dual Directional Pulse Test Set
Z5623A-H86 2GHz-40 GHz Uni Directional Pulse Test Set
Z5623A-H87 1GHz-50 GHz Dual Directional Pulse Test Set
Z5623A-H88 1GHz-50 GHz Dual Directional Pulse Test Set (No HPIB)
Z5623A-H89 10 MHz - 5 GHz Uni Directional Pulse Test Set (no HPIB)
Z5623A-H90 1GHz-50 GHz Dual Directional Pulse Test Set (Test Ports on Test Set)
Specifications & Attributes (Network Analyzers)
Form Factor
Rackmount ( /1CM /1CP )
Frequency
10 MHz - 40 GHz
Type
Vector Network Analyzer (VNA)

Request a Quote