Rohde and Schwarz ZVA40

Network Analyzer
Contact us for pricing and availability.
Description

With its new R&S ZVA family of vector network analyzers, Rohde & Schwarz is taking a future-oriented approach. The analyzers offer a perfect balance between measurement speed, dynamic range, flexibility and precision, making them ideal for present and future measurement tasks.

Rohde & Schwarz previously set standards in RF and microwave measurements with its R&S ZVR family of network analyzers, and now continues this success with the R&S ZVA. The fundamental mixing concept employed by the receivers ensures high sensitivity and a wide dynamic range. Extremely fast synthesizers make for short measurement times. Its excellent characteristics, new functionality, sophisticated GUI and extremely high flexibility make the R&S ZVA an indispensable tool for demanding measurement tasks in labs and production.

  • Multiport concept
  • Highest network analyzer performance
  • Versatile functionality
  • High measurement speed
  • Modern user interface (Windows)
  • GPIB, LAN, USB
  • Pulsed profile measurement option
  • True differential Measurements option

Note: Image is of ZVA24

List of Options
B-B18 Removable Flash Disk 4GB for ZVA/ZVB with control unit FMR6/5 (factory installed only)
B-B18 Removable Flash Disk 4GB for ZVA/ZVB with controller unit FMR7/3 or FMR7/6
B-B18 Removable hard disk 160GB (including firmware) for R&S® ZVA and R&S® ZVB with FMR7
B-B4 Oven quartz (OCXO) for ZVA, ZVB, ZVT
B-K2 Time domain (for ZVA, ZVB, ZVT) (software license)
B-K30 Noise figure measurement on 2 port devices (for ZVA and ZVT,
B16 Direct Generator and Receiver Access for 2 Ports
B18 Removable Flash Disc
B21 Generator Step Attenuator Port 1; mechanical, 70dB in 10dB-steps
B22 Generator Step Attenuator Port 2; mechanical, 70dB in 10dB-steps
B23 Generator Step Attenuator Port 3; mechanical, 70dB in 10dB-steps, 40 GHz
B24 Generator Step Attenuator Port 4; mechanical, 70dB in 10dB-steps, 40 GHz
B31 Receiver Step Attenuator Port 1; mechanical, 35dB in 5dB-steps
B32 Receiver Step Attenuator Port 2; mechanical, 35dB in 5dB-steps
B33 Receiver Step Attenuator Port 3; mechanical, 35dB in 5dB-steps, 40GHz
B34 Receiver Step Attenuator Port 4; mechanical, 35dB in 5dB-steps, 40GHz
B7 Measurements on pulsed signals. Pulse Profile,Recording time up to 25ms, up to 30MHz bandwidth
B7 Measurements on pulsed signals. Pulse profile,Recording time up to 25ms, up to 30MHz bandwidth
B8 External attenuator control. Control unit for electronic attenuators of ZVAZ90E, ZVA-Z110E
C3 hree years of depot calibration coverage based on the R&S recommended calibration interval - includes test data.
C3 Three years of depot calibration coverage based on the R&S recommended calibration interval - includes test data.
C5 Five years of depot calibration coverage based on the R&S recommended calibration interval - includes test data.
C5 Five years of depot calibration coverage based on the R&S recommended calibration interval - includes test data.
DCV-2 Documentation of calibration values
DCV-ZP Printout of DCV (additional, in combination with DCV-Option only)
K10 Group delay measurement on converters without LO access. For long distances via LXI network of 2 ZVA or ZVT.
K17 Increases the receiver bandwidth to 5MHz (software license)
K2 Time domain (for ZVA, ZVB, ZVT)
K27 Two internal pulse generators (for ZVA and ZVT) (software license)
K4 Mixer- and frequency converting measurements for ZVA and ZVT (software license)
K5 Vector corrected mixer measurements (for R&S®ZVA, R&S®ZVT; R&S®ZVA/T-B16 and R&S®ZVA-K4 required)
K6 True Differential Measurements for all 4-port ZVA and for ZVT with at least 3 ports
K7 Measurements on pulsed signals pulse profile, recording time up to 3ms up to 30 MHz bandwidth
K8 Control of frequency converters (for ZVA with f>20 GHz, ZVT20, includes ZVA-K4)
K9 Measurement of group delay on frequency converters without LO access (for ZVA, ZVT;
R3 Three years of depot repair coverage, including re-calibration if necessary to complete the repair.
R3 Three years of depot repair coverage, including re-calibration if necessary to complete the repair.
R5 Five years of depot repair coverage, including re-calibration if necessary to complete the repair.
R5 Five years of depot repair coverage, including re-calibration if necessary to complete the repair.
Specifications & Attributes (Network Analyzers)
Form Factor
Benchtop
Frequency
300 KHz - 40 GHz
Type
Vector Network Analyzer (VNA)
Documents and Downloads