Rohde and Schwarz ZVA67

Vector Network Analyzer. 2 ports, 10MHz-67GHz; 1.85mm(m) test ports
Contact us for pricing and availability.
Description
List of Options
B-B18 Removable Flash Disk 4GB for ZVA/ZVB with controller unit FMR7/3 or FMR7/6
B-B18 Removable hard disk 160GB (including firmware) for R&S® ZVA and R&S® ZVB with FMR7
B-B4 Oven quartz (OCXO) for ZVA, ZVB, ZVT
B-K2 Time domain (for ZVA, ZVB, ZVT) (software license)
B-K30 Noise figure measurement on 2 port devices (for ZVA and ZVT,
B16 Direct generator-receiver-access (for 2 port ZVA67)
B21 Generator Step Attenuator Port 1, mechanical, 50dB in 10dB steps
B22 Generator Step Attenuator Port 2, mechanical, 50dB in 10dB steps
B23 Generator Step Attenuator Port 3, mechanical, 50dB in 10dB steps
B24 Generator Step Attenuator Port 4, mechanical, 50dB in 10dB steps
B31 Receiver Step Attenuator Port 1, mechanical, 35dB in 5dB steps
B32 Receiver Step Attenuator Port 2, mechanical, 35dB in 5dB steps
B33 Receiver Step Attenuator Port 3, mechanical, 35dB in 5dB steps
B34 Receiver Step Attenuator Port 4, mechanical, 35dB in 5dB steps
B7 Measurements on pulsed signals. Pulse profile,Recording time up to 25ms, up to 30MHz bandwidth
B8 External attenuator control. Control unit for electronic attenuators of ZVAZ90E, ZVA-Z110E
C3 Three years of calibration coverage based on the R&S recommended calibration interval - includes test data.
C3 Three years of calibration coverage based on the R&S recommended calibration interval - includes test data.
C5 Five years of calibration coverage based on the R&S recommended calibration interval - includes test data.
C5 Five years of calibration coverage based on the R&S recommended calibration interval - includes test data.
DCV-2 Documentation of calibration values
DCV-ZP Printout of DCV (additional, in combination with DCV-Option only)
K10 Group delay measurement on converters without LO access. For long distances via LXI network of 2 ZVA or ZVT.
K17 Increases the receiver bandwidth to 5MHz
K27 Two internal pulse generators (for ZVA and ZVT)
K4 Frequency converting measurement for ZVA and ZVT
K5 Phase measurement on mixers (for ZVA, ZVT; ZVA/T-B16 and ZVA-K4 required)
K6 True Differential Measurements for all 4-port ZVA and for ZVT with at least 3 ports
K7 Measurements on pulsed signals pulse profile, recording time up to 3ms up to 30 MHz bandwidth
K8 Control of frequency converters (for ZVA with f>20 GHz, ZVT20, includes ZVA-K4)
K9 Measurement of group delay on frequency converters without LO access (for ZVA, ZVT;
R3 Three years of depot repair coverage, including recalibration and test data if necessary to complete a repair -
R3 Three years of depot repair coverage, including recalibration and test data if necessary to complete a repair -
R5 Five years of depot repair coverage, including recalibration and test data if necessary to complete a repair -
R5 Five years of depot repair coverage, including recalibration and test data if necessary to complete a repair -
ZV-Z218 1,85 mm calibration kit, fixed match, TOSM male and female calibration standards
ZV-Z96 Flexible Precision Cable 50 Ohm 1.85mm(f)Rugged. to 1.85mm(m)Rugged.DUT; DC to 67GHz; 635mm(25 inch); 1 piece
ZVAB-B18 Removable Flash Disc for ZVA/ZVB with controller unit FMR7/3 or FMR7/6
ZVAB-B4 Oven quartz (OCXO) for ZVA, ZVB, ZVT
ZVAB-K2 Time domain (for ZVA, ZVB, ZVT)
ZVAB-K30 Noise figure measurement on linear and frequency converting 2 port devices (for ZVA, ZBV and ZVT,
Specifications & Attributes (Network Analyzers)
Frequency
5 MHz ( /K17 )
30 MHz ( /B7 /K7 )
20 GHz ( /K8 )
67 GHz ( /ZV-Z96 )
10 MHz - 67 GHz
Type
Vector Network Analyzer (VNA)

Request a Quote