Rohde and Schwarz NRVS

Single Channel Power Meter
Contact us for pricing and availability.
Description
The Rohde NRVS is a Single Channel Power Meter.
    Performance Characteristics
  • Form Factor Benchtop
  • Number of Channels 1 ch
  • Minimum Frequency 0 Hz
  • Maximum Frequency 26.5 GHz
  • Minimum Log Display Resolution 0.001 dB
  • Maximum Log Display Resolution 0.1 dB
  • Programmability/Connectivity
  • User Interface Proprietary
  • Ports to Peripheral Devices IEEE488
  • Life Cycle Data
  • Out of Production Sep-30-2003
  • Compliance
  • CE Compliance Not on file
  • UL Compliance Not compliant
  • Input Power
  • Universal (Auto Sense and Switch)
List of Options
1R Rack mount Adapter ZZA-94
B1 Sensor check source 1 mW 50 MHz for NRVS, URV35 and URV55
C3 Three years of depot calibration coverage based on the R&S recommended calibration interval - includes test data. The first calibration is included with product delivery with 1 additional depot calibration(s).
C5 Five years of calibration coverage based on the R&S recommended calibration interval - includes test data. The first calibration is included with product delivery with 2 additional depot calibration(s).
D1 Calibration Data Report
DCV-1 Documentation of calibration values
DCV-ZP Printout of DCV (additional, in combination with DCV-Option only)
NRV-Z1 POWER CENSOR 50 OHM
NRV-Z51 THERMAL POWER SENSOR 50 OHM
R3 Three years of depot repair coverage, including re-calibration if necessary to complete the repair. First year of repair coverage is provided by the 12-month new product warranty.
R5 Five years of depot repair coverage, including re-calibration if necessary to complete the repair. First year of repair coverage is provided by the 12-month new product warranty.
S1 Service kit for NRVS and URV55
Z15 Power sensor 50 Ohm 50 MHz - 40 GHz, 400 pW - 20 mW K(2.92 mm) male, 1.3 m (4 ft) cable
Z31 Peak power sensor 50 Ohm 30 MHz - 6 GHz, standard model 1 µW - 20 mW
Z32 Peak power sensor 50 Ohm 30 MHz - 6 GHz, 100 µW - 2 W TDMA model
Z32 Peak power sensor 50 Ohm 30 MHz - 6 GHz, 100 µW - 2 W universal model
Z33 Peak power sensor 50 Ohm 30 MHz - 6 GHz, 1 mW - 20 W high speed model
Z33 Peak power sensor 50 Ohm 30 MHz - 6 GHz, 1 mW - 20 W TDMA model
Z4 Power sensor 50 Ohm 100 kHz - 6 GHz, 100 pW - 20 mW N-connector male, 1.3 m (4 ft) cable
Z4 Power sensor 50 Ohm 100 kHz - 6 GHz, 100 pW - 20 mW N-connector male, 5 m (16 ft) cable
Z5 Power sensor 50 Ohm 100 kHz - 6 GHz, 10 nW - 500 mW N-connector male, 1.3 m (4 ft) cable
Z5 Power sensor 50 Ohm 100 kHz - 6 GHz, 10 nW - 500 mW N-connector male, 5 m (16 ft) cable
Z51 Thermal power sensor 50 Ohm 0 - 18 GHz, 1 µW - 100 mW N-connector male, 1.3 m (4 ft) cable
Z52 Thermal power sensor 50 Ohm 0 - 26.5 GHz, 1 µW - 100 mW 3.5 mm male, 1.3 m (4 ft) cable
Z53 Thermal power sensor 50 Ohm 0 - 18 GHz, N-connector 100 µW - 10 W
Z54 Thermal power sensor 50 Ohm 0 - 18 GHz, N-connector 300 µW - 30 W
Z55 Thermal power sensor 50 Ohm 0 - 40 GHz, 1 µW - 100 mW K (2.92 mm) male, 1.3 m cable
Z6 Power sensor 50 Ohm 50 MHz - 26.5 GHz, 400 pW - 20 mW PC 3.5 mm male, 1.3 m (4 ft) cable
Specifications & Attributes (Power Meter)