Keysight (Agilent) 85093C

RF Electronic Calibration Module, 300 kHz to 9 GHz, 3.5 mm, 2-port
Contact us for pricing and availability.
Description
The Agilent 85093C RF electronic calibration (ECal) module makes calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and number of connections using ECal versus mechanical cal kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.

ECal modules are transfer standards capable of transferring the factory calibration accuracy to your network analyzer. The new 85093C RF electronic calibration system is now easily controlled by one of two methods depending on the network analyzer. The Agilent PNA and ENA series of network analyzers controls the module directly through a USB interface. The Agilent 8753E/ES/ET network analyzers require an 85097B interface kit to control the module.

Features:
  • 300 kHz to 9 GHz frequency range
  • Fast full two-port calibration with a single connection
  • Simple non-insertable device calibration
  • NIST traceable accurate calibrations
  • Reduced connector wear
  • USB interface for direct control with PNA and ENA series of network analyzers
  • Reliable solid-state switching
  • Mixed connector options available (3.5 mm, Type-N 50 ohm, and 7-16)
List of Options
00A Adds male-to-male and female-to-female adapters (also adds a 5/16” 90 N-cm (8 in-lb) torque wrench to 3.5 mm modules)
00F Both 3.5mm connectors are female on module
00M Both 3.5mm connectors are male on module
010 Four female, 3.5 mm connectors
020 Four female, Type-N 50 ohm connectors
101 Port A connector is 3.5mm female
102 Port A connector is 3.5mm male
103 Type N(f) on Port A
104 Type N(m) on Port A
105 7-16(f) on Port A
106 7-16(m) on Port A
150 Wooden storage box
1A7 ISO 17025 compliant calibration
203 Port B connector is Type-N 50-Ohm female
204 Port B connector is Type-N 50-Ohm male
205 Port B connector is 7-16 female
206 Port B connector is 7-16 male
85093-00A Add 3.5 mm adapters
A6J ANSI Z540 compliant calibration
C02 3.5mm (f) QMA adapters attached and characterized to standard 3.5mm (f) module; limits operation to 3 GHz
H6J ANSI Z540 compliant calibration
M0F One female and one male connector, both 3.5 mm
R-50C-011-3 Agilent Calibration - 3 years
R-50C-011-5 Agilent Calibration - 5 years
R-50C-016-3 ISO 17025 Compliant Calibration - 3 years
R-50C-016-5 ISO 17025 Compliant Calibration - 5 years
R-50C-021-3 ANSI Z540-1-1994 Calibration - 3 years
R-50C-021-5 ANSI Z540-1-1994 Calibration - 5 years
RMKT Agilent Refurbished Product (Do Not Use - Certiprime Option)
UK6 Commercial calibration certificate with test data