Instek GPT-9804

Hi-Pot Tester, AC/DC/IR/GB
Contact us for pricing and availability.
Description

The specifications apply when the GPT-9800 is powered on for at least 30 minutes under +15°C~+35°C.

Model \ Func. GPT-9804 GPT-9803 GPT-9802 GPT-9801
AC WITHSTANDING v v v v
DC WITHSTANDING v v v ×
INSULATION RESISITANCE v v × ×
GROUND BOND v × × ×

 

 AC WITHSTANDING
 Output-Voltage Range  0.050kV~ 5.000kV ac 
 Output-Voltage Resolution   2V/step 
 Output-Voltage Accuracy  ± (1% of setting +5V) [no load] 
 Maximum Rated Load  200 VA (5kV/40mA) 
 Maximum Rated Current  40mA (0.5kV < V ? 5kV)  
 10mA (0.1kV ? V? 0.5kV) 
 Output-Voltage Waveform  Sine wave
 Output-Voltage Frequency  50 Hz / 60 Hz selectable 
 Voltage regulation  ± (1% of reading +5V) [full load →no load] 
 Voltmeter Accuracy   ± (1% of reading+ 5V) 
 Current Measurement Range  0.001mA~040.0mA 
 Current Best Resolution  0.001mA / 0.01mA / 0.1mA 
 AC Current Measurement Accuracy  ±(1.5% of reading +30 counts) when HISET < 1.11mA  
 ±(1.5% of reading +3 counts) when HISET ? 1.11mA  
 Window Comparator Method  Yes
 ARC Detect  Yes 
 RAMP (Ramp-Up Time)   0.1~999.9s 
 TIMER (Test Time)*   OFF**, 0.5s~999.9s 
 GND  ON/OFF 
 DC WITHSTANDING
 Output-Voltage Range  0.050kV~ 6.000kV dc 
 Output-Voltage Resolution  2V/step 
 Output-Voltage Accuracy  ± (1% of setting +5V) [no load] 
 Maximum Rated Load   50W (5kV/10mA) 
 Maximum Rated Current  10mA (0.5kV < V ? 6kV)  
 2mA (0.05kV ? V? 0.5kV) 
 Voltage regulation   ± (1% of reading +5V) [[full load → no load] 
 Voltmeter Accuracy  ± (1% of reading+ 5V) 
 Current Measurement Range  0.001mA~010.0mA 
 Current Best Resolution  0.001mA / 0.01mA / 0.1mA 
 DC Current Measurement Accuracy  ±(1.5% of reading +30 counts) when HISET < 1.11mA  
 ±(1.5% of reading +3 counts) when HISET ? 1.11mA 
 Window Comparator Method  Yes
 ARC Detect  Yes
 RAMP (Ramp-Up Time)   0.1~999.9s 
 TIMER (Test Time)*  OFF**, 0.5s~999.9s 
 GND  ON/OFF 
 INSULATION RESISITANCE
 Output-Voltage  50V~1000V dc 
 Output-Voltage Resolution   50V/step 
 Output-Voltage Accuracy  ± (1% of setting +5V) [no load] 
 Resistance Measurement Range   1 MΩ~ 9500 MΩ 
 Test voltage  Measurable Range  Accuracy
 50V?V?450V  1 MΩ~ 50 MΩ
 51 MΩ~ 2000 MΩ
 ±(5% of reading +1 count)
 ±(10% of reading +1 count)
 500V?V?1000V   1 MΩ~ 500 MΩ
 501 MΩ~ 9500 MΩ
 ±(5% of reading +1 count)
 ±(10% of reading +1 count)
 Window Comparator Method   Yes               
 Output Impedance  600 kΩ    
 RAMP (Ramp-Up Time)   0.1~999.9s
 TIMER (Test Time)*  1s~999.9s
 GND   OFF (fixed)
 GROUND BOND
 Output-Current Range  03.00A~30.00A ac
 Output-Current Resolution  0.01A
 Output-Current Accuracy  3A?I?8A : ± (1% of setting +0.2A)
 8A<I?30A : ± (1% of setting +0.05A)
 Test-Voltage  6Vac max. (open circuit)
 Test-Voltage Frequency  50 Hz / 60 Hz selectable
 Resistance Measurement Range  10mΩ~650.0mΩ
 Resistance Measurement Resolution  0.1mΩ
 Resistance Measurement Accuracy  ± (1% of reading +2mΩ)
 Window Comparator Method  Yes
 TIMER (Test Time)*  0.5s~999.9s
 GND  OFF (fixed)
 Test Method  Four Terminal
 MEMORY
 Single Step Memory  MANU : 100 blocks
 Automatic Testing Memory  AUTO : 100 blocks, menu per auto : 16
 INTERFACE
 RS232   Standard 
 USB (Device)   Standard 
 GPIB  Option
 Remote Terminal (Front)  Standard 
 SIGNAL IO  Standard 
 GENERAL
 Display  240 x 64 dot matrix LED back light LCD
 Power Source  AC100V/120V/220V/230V ±10%, 50/60Hz
 Power Consumption  500VA max.
 Dimensions & Weight  330(W) x 148(H) x 452(D) mm (Max.),
 approx.19kg(Max)
  * TIMER Accuracy: ± (100ppm + 20ms)
  **The “TIMER OFF” can only be performed when the tester is in the special MANU mode

Request a Quote