Rohde and Schwarz ZVT8

Network Analyzer
Contact us for pricing and availability.
Description

The R&S ZVT8 is the first true 8 GHz vector network analyzer with up to eight test ports. Its design, operation, functions and specifications are very similar to those of an R&S ZVB without a display and front panel keypad. The R&S ZVT8 uses the R&S ZVB firmware.

A basic two-port R&S ZVT8 can be expanded to a vector network analyzer with up to eight ports by adding the appropriate options. If this is done, S-parameters of coaxial multiports (up to 8 ports) and mixed-mode S-parameters can be determined on balanced or symmetrical DUTs.

The R&S ZVT8 is primarily designed for system solutions in which it is remote-controlled via an IEC/IEEE bus or LAN. By adding an external monitor, mouse and keyboard to the R&S ZVT8, you can use it (like the R&S ZVB) as a mouse-operated standalone instrument in a lab environment by using pull-down menus.

Unlike conventional multiport solutions based on two- or four-port network analyzers with corresponding switching matrices, each port of the R&S ZVT8 has its own reflectometer with VSWR bridge, generator and measurement and reference receiver.

Each reflectometer can also be equipped with the Direct Generator/Receiver Access option. In this case, the generator and receiver paths are routed via the front panel by means of an removable 3.5 mm PC cable link. This option is comparable to the External Measurements option of the R&S ZVR family, additionally allowing direct access to the generator path before the reference receiver.

  • Frequency range 300 kHz to 8 GHz
  • Test set configuration possible with two up to eight ports
  • Wide dynamic range > 120 dB (test port)
  • High output power > 13 dBm on all ports
  • Wide power sweep range - 40 dBm to 13 dBm
  • High measurement speed of 8 ms for an eight port measurement
  • High accuracy and reproducibility on all ports
  • Modern operating concept for quickly and easily selecting parameters
  • Quick and easy configuration of multiport measurements
  • Virtually unlimited number of channels and traces
  • Parallel setup administration
  • Measurement on balanced DUTs
  • Based on a true multiport architecture the R&S ZVT8 can perform measurements on all ports of a DUT simultaneously
  • DC inputs for current and voltage measurements
  • Direct Receiver / Generator Access option for greater flexibility and performance
  • True differential Measurements option
List of Options
.C5 Five years of calibration coverage based on the R&S recommended calibration interval - includes test data.
.R3 Three years of depot repair coverage, including re-calibration if necessary to complete the repair.
.R5 Five years of depot repair coverage, including re-calibration if necessary to complete the repair.
B16 Direct generator/receiver access
B63 Additional Port 3 (Port 1 and Port 2 standard)
B64 Additional Port 4 (Requires Port 1 to Port 3)
B65 Additional Port 5 (Requires Port 1 to Port 4)
B66 Additional Port 6 (Requires Port 1 to Port 5)
B67 Additional Port 7 (Requires Port 1 to Port 6)
B68 Additional Port 8 (Requires Port 1 to Port 7)
C3 Three years of depot calibration coverage based on the R&S recommended calibration interval - includes test data. The first calibration is included with product delivery with 2 additional depot calibration(s).
DCV-2 Documentation of calibration values
DCV-ZP Printout of DCV (additional, in combination with DCV-Option only)
ZVA-B7 Measurements on pulsed signals. Pulse profile,Recording time up to 25ms, up to 30MHz bandwidth
ZVA-K10 Group delay measurement on converters without LO access. For long distances via LXI network of 2 ZVA or ZVT.
ZVA-K17 Increases the receiver bandwidth to 5MHz
ZVA-K27 Two internal pulse generators (for ZVA and ZVT)
ZVA-K4 Frequency converting measurement for ZVA and ZVT
ZVA-K5 Phase measurement on mixers (for ZVA, ZVT; ZVA/T-B16 and ZVA-K4 required)
ZVA-K6 True Differential Measurements for all 4-port ZVA and for ZVT with at least 3 ports
ZVA-K7 Measurements on pulsed signals pulse profile, recording time up to 3ms up to 30 MHz bandwidth
ZVA-K9 Measurement of group delay on frequency converters without LO access (for ZVA, ZVT;
ZVAB-B4 Oven quartz (OCXO) for ZVA, ZVB, ZVT
ZVAB-K2 Time domain (for ZVA, ZVB, ZVT)
ZVAB-K30 Noise figure measurement on linear and frequency converting 2 port devices (for ZVA, ZBV and ZVT,
ZVT8.C5 Five years of calibration coverage based on the R&S recommended calibration interval - includes test data. The first calibration is included with product delivery with 4 additional depot calibration(s).
ZVT8.R3 Three years of depot repair coverage, including re-calibration if necessary to complete the repair. First year of repair coverage is provided by the 12-month new product warranty
ZVT8.R5 Five years of depot repair coverage, including re-calibration if necessary to complete the repair. First year of repair coverage is provided by the 12-month new product warranty.
Specifications & Attributes (Network Analyzers)
Form Factor
Benchtop
Frequency
5 MHz ( /ZVA-K17 )
30 MHz ( /ZVA-B7 /ZVA-K7 )
300 KHz - 8 GHz
Type
Vector Network Analyzer (VNA)
Documents and Downloads

Request a Quote