Keysight (Agilent) N4692A

Electronic Calibration Module, 10 MHz to 40 GHz, 2.92 mm, 2-port
Contact us for pricing and availability.
Description
The Agilent N4692A MW electronic calibration (ECal) module makes calibration of vector network analyzers fast, easy and accurate. The RF ECal system is now easily controlled by one of two methods depending on the network analyzer. The Agilent PNA and ENA series of network analyzers controls the module directly via the USB interface. The modules can also be controlled via an 85097B interface kit when used with an Agilent 8753E/ES/ET or 8720D/ES/ET. (This requires a special parallel cable and firmware Rev. 7.74).

ECal is an ideal solution for calibrating network analyzers. Performing a full two-port calibration takes less than half the time and number of connections using ECal versus mechanical cal kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.

Features:
  • 10 MHz to 40 GHz frequency range
  • USB interface for direct control with PNA and ENA series of network analyzers
  • Alternative 85097B interface when used with other analyzers
  • Fast calibration
  • Full two-port calibration with a single connection
  • Reduced connector wear
  • NIST traceable accurate calibrations
  • Reliable solid-state switching
List of Options
00A Add 2.92 mm adapters
00F Both 2.92 mm connectors are female on module
00M Both 2.92 mm connectors are male on module
150 Wooden storage box
1A7 ISO 17025 compliant calibration
A6J ANSI Z540 compliant calibration
M0F One female and one male connector, both 2.92 mm
R-50C-011-3 Agilent Calibration - 3 years
R-50C-011-5 Agilent Calibration - 5 years
R-50C-016-3 ISO 17025 Compliant Calibration - 3 years
R-50C-016-5 ISO 17025 Compliant Calibration - 5 years
R-50C-021-3 ANSI Z540-1-1994 Calibration - 3 years
R-50C-021-5 ANSI Z540-1-1994 Calibration - 5 years
UK6 Commercial calibration certificate with test data

Request a Quote