Rohde and Schwarz FSP40

Spectrum Analyzer, 9 KHz to 40 GHz
Contact us for pricing and availability.
Description
FSP is the ideal partner for both development and production, featuring the smallest level measurement uncertainty in its class, as well as excellent RF characteristics. The FSP is outstanding for its innovative measurement functions and incorporates proven technology with an all new hardware design to enable revolutionary performance, reliability and ease of service. Features
  • Frequency range 20Hz to 3GHz, 7 GHz, 13 GHz, 30 GHz and 40 GHz
  • Resolution bandwidth 1 Hz to 10 MHz
  • Displayed average noise level -155 dBm (1 Hz)
  • Phase noise -113 dB (1 Hz) at 10 kHz
  • Additional filters:
  • Channel filters from 100 Hz to 5 MHz and RRC filters; FFT filters from 1Hz to 30 kHz; EMI bandwidths and quasi-peak detector
  • Total measurement uncertainty 0.5 dB
  • Measurement routines for TOI, ACP(R), OBW, CCDF, APD, etc. as standard
  • Fast ACP in time domain
  • Up to 80 measurements per second (including trace transfer via GPIB)
  • Electronic attenuator
  • Application firmware available for GSM/EDGE, Bluetooth, WCDMA/HSDPA/TD-SCDMA, CDMA2000/1xEV-DV/1xEV-DO, WLAN, …
List of Options
B1 Rugged case with variable carrying handle for all FSP models
B10 External generator control for FSP, FSU, FSG, FSQ, ESU, ESCI, ESPI and for retrofit of
B15 Pulse calibrator for FSP excludes option FSP-B3
B16 LAN interface 10/100 base T for FSP 1164.4391.XX and ESPI 1164.6407.XX
B18 Removable hard disk with WinXP (factory installed)
B19 Second hard disk for FSP-B18 analyzer firmware for FSP with WinXP included
B1G CPU RAM upgrade to 1GB. To upgrade FSP with CPU board (1091.2895.00) with less than 1GB
B20 Extended environment Spec, Random Vibration 1.9G / 0 - 55°C (not retrofittable)
B21 LO/IF connections for external mixers for FSP40
B28 Trigger port for FSP,FSQ,FSU; for indication of trigger conditions
B29 20 Hz frequency extension to FSP40 Not retrofittable
B3 Audio demodulator AM/FM for FSP internal speaker, control and phones connection
B30 DC power supply 12 - 28 V for FSP spectrum analyzer and ESPI test receiver
B31 NiMH battery pack + charger for FSP and ESPI requires FSP-B1 and FSP-B30
B32 Spare battery pack (NiMH) for FSP spectrum analyzer and ESPI test receiver
B33 Disabled USB ports, excludes FS-K9
B4 OCXO 10 MHz for FSP
B6 TV trigger and adjustable RF power trigger (40 dB) for FSP
B70 Demodulator hardware and memory extension for FS-K72/FS-K73 on FSP
B9 Tracking generator for FSP 9 kHz - 3 GHz, I/Q modulator
C3 Three years of depot calibration coverage based on the R&S recommended calibration interval - includes test data. The first calibration is included with product delivery with 2 additional depot calibration(s).
C5 Five years of calibration coverage based on the R&S recommended calibration interval - includes test data. The first calibration is included with product delivery with 4 additional depot calibration(s).
DCV-2 Documentation of calibration values
DCV-ZP Printout of DCV (additional, in combination with DCV-Option only)
DKD FSP40 DKD (ISO17025) calibration incl. ISO 9000 calibration (order only with device)
FS-B33 USB mass memory write protection, disables writing to USB memory sticks (ex factory only)
FS-K30 Application firmware for noise figure and gain measurements for FSMR, FSP, FSQ, FSU
FS-K40 Application firmware for phase noise measurements for FSMR, FSP, FSQ, FSU
FS-K5 Application firmware GSM/EDGE tests for FSP, FSU, FSQ
FS-K7 FM demodulator, allows measurement of FM specific parameters (for FMU, FSP, FSU)
FS-K72 Application firmware 3GPP-FDD BTS transmitter test for FSMR, FSP, FSU, FSQ
FS-K73 Application firmware 3GPP-FDD UE transmitter test for FSMR, FSP, FSU, FSQ
FS-K73+ 3GPP HSPA+ UE transmitter test, application firmware (for FSMR, FSP, FSQ, FSU, FSUP,
FS-K74 3GPP HSDPA base station test application firmware for FSMR, FSU, FSP, FSQ
FS-K74+ 3GPP HSPA plus, base station test. Application firmware (for FSP, FSQ, FSU, FSG;
FS-K76 3GPP TD-SCDMA base station test; application firmware for FSMR, FSP, FSQ, FSU
FS-K77 3GPP TD-SCDMA mobile station test; application firmware for FSMR, FSP, FSQ, FSU
FS-K8 Application firmware for Bluetooth measurement on FSP, FSU and FSQ
FS-K82 CDMA2000/1xEV-DV base station test application firmware for FSMR, FSP, FSU, FSQ
FS-K83 CDMA2000/1xEV-DV mobile station application firmware for FSMR, FSP, FSQ, FSU
FS-K84 1xEV-DO base station test application firmware for FSMR, FSU, FSP, FSQ
FS-K85 1xEV-DO mobile station test application firmware for FSMR, FSP, FSQ, FSU
FS-K9 Measurements with NRP power sensors NRP-Z11/Z21/Z22/Z23/Z24/Z51/Z55/Z91 requires NRP-Z3 or NRP-Z4
FSP40DKD FSP40 DKD (ISO17025) calibration incl. ISO 9000 calibration (order only with device)
K5 Application firmware GSM/EDGE tests for FSP, FSU, FSQ
K90 Application firmware WLAN 802.11A TX tests (EVM, flatness, mask) for FSP
K93 Application firmware for WIMAX 802.16; OFDM/OFDMA measurements
R3 REPAIR SERVICE 3 YEARS
R5 Five years of depot repair coverage, including re-calibration if necessary to complete the repair. First year of repair coverage is provided by the 12-month new product warranty.
Specifications & Attributes (Spectrum Analyzers)
Form Factor
Benchtop
Portable
Application Software
Bluetooth ( /FS-K8 )
CDMA2000 ( /FS-K83 )
GSM with Edge ( /K5 )
HSDPA ( /FS-K74 )
Noise Figure ( /FS-K30 )
Phase Noise ( /FS-K40 )
TD-SCDMA ( /FS-K77 )
Average Noise Level
-155 dBm
Frequency
20 Hz ( /B29 )
10 MHz ( /B4 )
9 KHz - 3 GHz ( /B9 )
9 KHz - 40 GHz

Request a Quote