| 015 | 1.5m cable length (for mainframe bundled cables and for package options) |
| 030 | 3m cable length (for mainframe bundled cables and for package options) |
| 050 | 50Hz Line Frequency |
| 060 | 60Hz Line Frequency |
| 1CM | Rack Mount Kit for B1500 Series |
| A00 | Standard Pack 0 - Empty Package for Custom Solution (No module is included.) |
| A01 | Standard Pack 1 -Standard Package (Mid PWR unit 4ea, Cables) |
| A02 | Standard Pack 2 -High Resolution Package (High Resolution unit 4ea, Cables) |
| A03 | Standard Pack 3 -High Power Package(High PWR unit 2ea, Mid PWR unit 2ea, Cables) |
| A04 | Standard Pack 4 - Flash Pack(Mid PWR unit 2ea, Hi-Res unit 2ea, PG, Accessories) |
| A10 | Add-on Package - High PoweBr Source Monitor Unit (1510A) 1ea, Cables |
| A11 | Add-on Package - Mid Power Source Monitor Unit (B1511A) 1ea, Cables |
| A17 | Add-on Package - High Resolution Source Monitor Unit (B1517A) 1ea, Cables |
| A20 | Add-on Package - Capacitance Measurement Unit (B1520A) 1ea, Cable 1ea |
| A25 | Add-on Package - Pulse Generator Unit (B1525A) 1ea, Cables |
| A28 | Add-on Package - Atto Sense Unit (E5288A) 1ea, Cables |
| A30 | Add-on Package - B1530A 1ea, Remote Sense Unit 2ea, Cables |
| A31 | Add-on Package - B1530A 1ea, Connector Adaptor, Remote Sense Unit 2ea, Cables |
| A3P | Add-on Package - Probe cable kit for B1530A(8 probe cables. B1530A not included) |
| A5F | Add-on Pack - Test Fixture for packaged device (16442B 1ea) |
| A6J | ANSI Z540 compliant calibration |
| B1510A | High Power Source/Monitor Unit (HPSMU) 2 Slots |
| B1510A-FG | High Power Source/Monitor Unit Module for B1500 |
| B1511A | Medium Power Source/Monitor Unit (MPSMU) |
| B1511A- X4 | Medium Power Source/Monitor Unit (MPSMU) |
| B1511A-FG | Medium Power Source/Monitor Unit Module for B1500 |
| B1511A-X2 | Qty. 2 Medium Power Source/Monitor Unit (MPSMU) Installed |
| B1511B x4 | Medium Power SMU Modules |
| B1517A | High Resolution Source/Monitor Unit (HRSMU) |
| B1517A-ATO | High Resolution Source/Monitor Unit Module for B1500 |
| B1517A-X2 | Qty. 2 High Resolution Source/Monitor Unit (HRSMU) Installed |
| B1520A | Multi Frequency Capacitance Measurement Unit (MFCMU) |
| B1520A-FG | Multi Frequency Capacitance Measurement Unit Module for B1500 |
| B1525A | High voltage semiconductor pulse generator unit (HV-SPGU) |
| B1525A-FG | High Voltage Semiconductor Pulse Generator Unit Module for B1500 |
| B1530A | Waveform Generator/Fast Measurement Unit (WGFMU) Module for the B1500A |
| B1530A-001 | 0.6m/2.4m Cable set between WGFMU and RSU(2ea). Require prober I/F with adapter. |
| B1530A-002 | 3m Cable between WGFMU and RSU (2ea) |
| B1530A-003 | 5m Cable between WGFMU and RSU (2ea) |
| B1530A-004 | 0.6m/4.4m Cable set between WGFMU and RSU(2ea). Require prober I/F with adapter. |
| B1530A-005 | 1.5m Cable between WGFMU and RSU (2ea) |
| B1530A-0KN | Self-paced Sample Program Learning Kit for B1530A WGFMU |
| B1530A-ATO | Waveform Generator / Fast Measurement Unit. Including 2 RSU for each channel. |
| B1540A-001 | EasyEXPERT Software on B1500A with License To Use for Standard version |
| B1540A-002 | LTU for EasyEXPERT Software Plus on B1500A |
| B1540A-ATO | EasyEXPERT Software and Measurement Libraries |
| E3332C-900 | Power Cord - United Kingdom |
| E3332C-901 | Power Cord - Australia and New Zealand |
| E3332C-902 | Power Cord - Continental Europe |
| E3332C-903 | Power Cord - United States and Canada (120V) |
| E3332C-904 | Power Cord - United States and Canada (240V) |
| E3332C-906 | Power Cord - Switzerland |
| E3332C-912 | Power Cord - Denmark |
| E3332C-917 | Power Cord - Republic of South Africa and India |
| E3332C-918 | Power Cord - Japan |
| E3332C-919 | Power Cord - Israel |
| E3332C-920 | Power Cord - Argentina |
| E3332C-921 | Power Cord - Chile |
| E3332C-922 | Power Cord - China |
| E3332C-923 | Power Cord - South Africa |
| E3332C-927 | Power Cord - Thailand |
| E3332C-930 | Power Cord - Brazil |
| E3332C-931 | Power Cord - Taiwan |
| E3332C-932 | Power Cord - Cambodia |
| E5288A | Atto Sense and Switch Unit (ASU) |
| E5288A-001 | Triax and Dsub Cable for ASU (1.5M) |
| E5288A-002 | Triax and Dsub Cable for ASU (3M) |
| E5288A-ATO | Atto Sense and Switch Unit (ASU) |
| R-50C-011-3 | Agilent Calibration - 3 years |
| R-50C-011-5 | Agilent Calibration - 5 years |
| R-50C-021-3 | ANSI Z540-1-1994 Calibration - 3 years |
| R-50C-021-5 | ANSI Z540-1-1994 Calibration - 5 years |
| R-51B-001-3C | Return to Agilent Warranty - 3 years |
| R-51B-001-5C | Return to Agilent Warranty - 5 years |
| R-51B-001-C | Return to Agilent Warranty - 1 year |
| UK6 | Commercial cal. Certificate with test data |