Keysight (Agilent) 85092C

RF Electronic Calibration Module, 300 kHz to 9 GHz, Type-N, 50 ohm, 2-port
Contact us for pricing and availability.
Description
The Agilent 85092C RF electronic calibration (ECal) module makes calibration of vector network analyzers fast, easy, and accurate. The RF ECal system is now easily controlled by one of two methods depending on the network analyzer. The Agilent PNA and ENA series of network analyzers controls the module directly via the USB interface. The modules can also be controlled via an 85097B interface kit used with an Agilent 8753E/ES/ET or 8720D/ES/ET.

ECal is an ideal solution for calibrating network analyzers. Performing a full two-port calibration takes less than half the time and number of connections using ECal versus mechanical cal kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.

Features:
  • 300 kHz to 9 GHz frequency range
  • Fast full two-port calibration with a single connection
  • Simple non-insertable device calibration
  • NIST traceable accurate calibrations
  • Reduced connector wear
  • USB interface for direct control with PNA and ENA series of network analyzers
  • Reliable solid-state switching
List of Options
00A Add Type-N 50-Ohm adapters
00F Both Type-N 50-Ohm connectors are female on module
00M Both Type-N 50-Ohm connectors are male on module
010 Four female, 3.5 mm connectors
020 Four female, Type-N 50 ohm connectors
101 3.5 mm(f) on Port A
102 3.5 mm(m) on Port A
103 Port A connector is Type-N 50-Ohm female
104 Port A connector is Type-N 50-Ohm male
105 7-16(f) on Port A
106 7-16(m) on Port A
150 Wooden storage box
1A7 ISO 17025 compliant calibration
1A7 ISO 17025 Compliant Calibration
201 Port B connector is 3.5mm female
202 Port B connector is 3.5mm male
203 Type N(f) on Port B
204 Type N(m) on Port B
205 Port B connector is 7-16 female
206 Port B connector is 7-16 male
A6J ANSI Z540 compliant calibration
M0F One female and one male connector, both type-N 50 ohm
R-50C-011-3 Agilent Calibration - 3 years
R-50C-011-5 Agilent Calibration - 5 years
R-50C-016-3 ISO 17025 Compliant Calibration - 3 years
R-50C-016-5 ISO 17025 Compliant Calibration - 5 years
R-50C-021-3 ANSI Z540-1-1994 Calibration - 3 years
R-50C-021-5 ANSI Z540-1-1994 Calibration - 5 years
RMKT Agilent Refurbished Product (Do Not Use - Certiprime Option)
UK6 Commercial calibration certificate with test data

Request a Quote