The specifications apply when the GPT-9800 is powered on for at least 30 minutes under +15°C~+35°C.
Model \ Func. | GPT-9804 | GPT-9803 | GPT-9802 | GPT-9801 |
AC WITHSTANDING | v | v | v | v |
DC WITHSTANDING | v | v | v | × |
INSULATION RESISITANCE | v | v | × | × |
GROUND BOND | v | × | × | × |
AC WITHSTANDING | ||
Output-Voltage Range | 0.050kV~ 5.000kV ac | |
Output-Voltage Resolution | 2V/step | |
Output-Voltage Accuracy | ± (1% of setting +5V) [no load] | |
Maximum Rated Load | 200 VA (5kV/40mA) | |
Maximum Rated Current | 40mA (0.5kV < V ? 5kV) 10mA (0.1kV ? V? 0.5kV) |
|
Output-Voltage Waveform | Sine wave | |
Output-Voltage Frequency | 50 Hz / 60 Hz selectable | |
Voltage regulation | ± (1% of reading +5V) [full load →no load] | |
Voltmeter Accuracy | ± (1% of reading+ 5V) | |
Current Measurement Range | 0.001mA~040.0mA | |
Current Best Resolution | 0.001mA / 0.01mA / 0.1mA | |
AC Current Measurement Accuracy | ±(1.5% of reading +30 counts) when HISET < 1.11mA ±(1.5% of reading +3 counts) when HISET ? 1.11mA |
|
Window Comparator Method | Yes | |
ARC Detect | Yes | |
RAMP (Ramp-Up Time) | 0.1~999.9s | |
TIMER (Test Time)* | OFF**, 0.5s~999.9s | |
GND | ON/OFF | |
DC WITHSTANDING | ||
Output-Voltage Range | 0.050kV~ 6.000kV dc | |
Output-Voltage Resolution | 2V/step | |
Output-Voltage Accuracy | ± (1% of setting +5V) [no load] | |
Maximum Rated Load | 50W (5kV/10mA) | |
Maximum Rated Current | 10mA (0.5kV < V ? 6kV) 2mA (0.05kV ? V? 0.5kV) |
|
Voltage regulation | ± (1% of reading +5V) [[full load → no load] | |
Voltmeter Accuracy | ± (1% of reading+ 5V) | |
Current Measurement Range | 0.001mA~010.0mA | |
Current Best Resolution | 0.001mA / 0.01mA / 0.1mA | |
DC Current Measurement Accuracy | ±(1.5% of reading +30 counts) when HISET < 1.11mA ±(1.5% of reading +3 counts) when HISET ? 1.11mA |
|
Window Comparator Method | Yes | |
ARC Detect | Yes | |
RAMP (Ramp-Up Time) | 0.1~999.9s | |
TIMER (Test Time)* | OFF**, 0.5s~999.9s | |
GND | ON/OFF | |
INSULATION RESISITANCE | ||
Output-Voltage | 50V~1000V dc | |
Output-Voltage Resolution | 50V/step | |
Output-Voltage Accuracy | ± (1% of setting +5V) [no load] | |
Resistance Measurement Range | 1 MΩ~ 9500 MΩ | |
Test voltage | Measurable Range | Accuracy |
50V?V?450V | 1 MΩ~ 50 MΩ 51 MΩ~ 2000 MΩ |
±(5% of reading +1 count) ±(10% of reading +1 count) |
500V?V?1000V | 1 MΩ~ 500 MΩ 501 MΩ~ 9500 MΩ |
±(5% of reading +1 count) ±(10% of reading +1 count) |
Window Comparator Method | Yes | |
Output Impedance | 600 kΩ | |
RAMP (Ramp-Up Time) | 0.1~999.9s | |
TIMER (Test Time)* | 1s~999.9s | |
GND | OFF (fixed) | |
GROUND BOND | ||
Output-Current Range | 03.00A~30.00A ac | |
Output-Current Resolution | 0.01A | |
Output-Current Accuracy | 3A?I?8A : ± (1% of setting +0.2A) 8A<I?30A : ± (1% of setting +0.05A) |
|
Test-Voltage | 6Vac max. (open circuit) | |
Test-Voltage Frequency | 50 Hz / 60 Hz selectable | |
Resistance Measurement Range | 10mΩ~650.0mΩ | |
Resistance Measurement Resolution | 0.1mΩ | |
Resistance Measurement Accuracy | ± (1% of reading +2mΩ) | |
Window Comparator Method | Yes | |
TIMER (Test Time)* | 0.5s~999.9s | |
GND | OFF (fixed) | |
Test Method | Four Terminal | |
MEMORY | ||
Single Step Memory | MANU : 100 blocks | |
Automatic Testing Memory | AUTO : 100 blocks, menu per auto : 16 | |
INTERFACE | ||
RS232 | Standard | |
USB (Device) | Standard | |
GPIB | Option | |
Remote Terminal (Front) | Standard | |
SIGNAL IO | Standard | |
GENERAL | ||
Display | 240 x 64 dot matrix LED back light LCD | |
Power Source | AC100V/120V/220V/230V ±10%, 50/60Hz | |
Power Consumption | 500VA max. | |
Dimensions & Weight | 330(W) x 148(H) x 452(D) mm (Max.), approx.19kg(Max) |
|
* TIMER Accuracy: ± (100ppm + 20ms) | ||
**The “TIMER OFF” can only be performed when the tester is in the special MANU mode |