Keysight (Agilent) 8720ES

S-parameter Network Analyzer, 50 MHz to 20 GHz

Units Available for Purchase

Units currently in stock, configurations vary - Request a Quote for Details
Description
The 8720ES features solid-state switching S-Parameter test sets with full two-port error correction. The ES models contain a 55-dB step attenuator as a standard feature for wide output power range. Enhanced response calibration provides improved accuracy for transmission measurements by correcting for source match without the speed penalty of a full two-port calibration.

Adapter-removal calibration provides greater accuracy for measurements of non-insertable devices, such as devices with the same sex connectors on both ports or different connector types on port 1 and 2. The 8720 analyzers have a fast source that is fully synthesized, in either swept or stepped modes, with stability and accuracy within 10 ppm (typical). The 8720ES combines a fast, synthesized source with an integrated test set covering frequencies from 50MHz to 20GHz.

Features:
  • 50 MHz to 20GHz frequency coverage.
  • Choice of transmission/reflection or S-Parameter test sets.
  • Fast measurement speed and data-transfer rates.
  • Display up to four parameters at the same time.
  • Up to 105dB dynamic range.
  • Optional time domain, frequency offset, and high power measurements.
List of Options
007 Mechanical Transfer Switch
010 Time Domain Capability
012 Direct Sampler Access
050 Standard Test Set Configuration
085 High power test set: automatically includes mechanical transfer switch and direct sampler access
089 Frequency off-set mode for mixer measurement capability
0B0 Do not include manuals
0B1 Add Manual Set
0BV Service Documentation, Component Level
0BW Service Documentation, Assembly Level
1BN Military Standard 45662A Calibration Certification
1BP Military Standard 45662A Calibration with Test Data
1CM Rackmount Kit
1CP Rackmount and Handle Kit
1D5 High Stability Frequency Reference
400 Four-Sampler Test Set
701 Three Sampler Test Set
702 Standard solid state transfer switch
703 No sampler access
704 Standard configuration with no mixer measurement capability
800 Standard prog/service/user
860 Additional material required for combination #704 and #050
861 Additional material required for combination #085 and #704
862 Additional material required for combination #089 and #050
863 Additional material required for combination #085 and #089
864 Additional material required for combination #050 and #701
865 Additional material required for combination #703 and #050
ABF France Quick Users Guide (French localization)
ABJ Japan Quick Users Guide (Japanese localization)
H32 Configurable Test Set
H42 Option 012 and 400, IF links for channels A,B and R1 on front panel, R2 on rear panel.
H86 High Power option 400.
H87 High Power Configuration Test Set option 400.
R51B RETURN TO AGILENT WARRANTY & SRVC PLAN
RMKT Keysight Refurbished Product (Do Not Use - Certiprime Option)
UK6 Commercial calibration with test results data
W50 5 Year Customer Return Repair Service
Specifications & Attributes (Network Analyzers)
Form Factor
Rackmount ( /1CM /1CP )
Frequency
50 MHz - 20 Ghz
Type
Vector Network Analyzer (VNA)

Request a Quote