Keysight (Agilent) 54754A

Differential & single-ended TDR/TDT module
Contact us for pricing and availability.
Description
The Agilent 54754A provides two 18-GHz channels that have built-in TDR step generators. The two channels may work in tandem to provide differential or common mode TDR stimulus/response, or may be used independently. Either channel works as a normal oscilloscope vertical system when the TDR/TDT step generators are not operating.

To protect your investment, you may want to consider using an ESD Protective device such as the one available from Picosecond ATE.

Probing And Calibration

Accurate probing of high-speed differential circuits can be a challenge. It is important to use a differential TDR probe with the correct bandwidth, pitch, signal configuration, etc. to match your design.

  • N1020A 6 GHz Single-ended TDR Probe & Positioner Kit
  • N1021B 18 GHz Differential TDR/TDT Probe Kit
  • N1024A TDR Calibration Kit

System configuration:

All 86100A/B/Cs and the 86100D in the ETR configuration have a internal trigger connections between modules and the mainframe. 86100Ds with option STR do not and therefore require an external cable (such as P/N 5062-6690) from the TDR module’s trigger output to the mainframe’s trigger input. Use a power splitter (such as P/N 11667B) or divider (such as P/N 11636B) when using two TDR modules in an 86100D mainframe with option STR.

Two 18 GHz electrical channels with 3.5 mm (m) connectors

  • Characteristic rms noise: 0.25 mV (12.4 GHz BW), 0.5 mV (18 GHz BW)
  • Maximum input signal: ± 2 Vdc
  • Two built-in step generators configurable for 1-port, 2-port common mode, or 2-port differential TDR or TDT measurements
  • Built-in TDR/TDT calibration, user-selectable edge speed, S-Parameters (requires mainframe FW rev. A.06.01 or later. S-parameters requires option 202)

Compatibility

  • 54750A High-Bandwidth Digitizing Oscilloscope Mainframe
  • 83480A Digital Communications Analyzer Mainframe
  • 86100A/B/C Infiniium DCA/DCA-J Mainframes
  • 86100D Infiniium DCA-X Mainframe

Accessories:

  • Probing - refer to the ''Description'' section below for information on single-ended and differential TDR probes.
  • TDR Calibration Kit - ensure measurement accuracy
  • ESD Protection – see Model 1202 from Picosecond ATE.
List of Options
001 Agilent 83480A mainframe operating system upgrade
002 Agilent 54750A mainframe operating system upgrade
003 Delete the demo board
004 Latest revision of 86100B firmware
0B1 Add Manual Set
100 RF accessory kit
86100CK-002 Latest 86100B/C Firmware Upgrade Kit
N1020A TDR Probe
N1024A TDR Calibration Kit
N9355CK01 DC coupled limiter
R-50C-011-3 Agilent Calibration - 3 years
R-50C-011-5 Agilent Calibration - 5 years
R-50C-021-3 ANSI Z540-1-1994 Calibration - 3 years
R-50C-021-5 ANSI Z540-1-1994 Calibration - 5 years
R-51B-001-3C Return to Agilent Warranty - 3 years
R-51B-001-5C Return to Agilent Warranty - 5 years
R-51B-001-C Return to Agilent Warranty - 1 year
RMKT Agilent Refurbished Product (Do Not Use - Certiprime Option)
Specifications & Attributes (Oscilloscopes)
Form Factor
Plug-In

Request a Quote