Keysight (Agilent) DSO91304A

Infiniium High Performance Oscilloscope: 13 GHz
Contact us for pricing and availability.
Description
The Infiniium DSO90000 series boasts industry-leading technology that allows for superior oscilloscope performance that goes beyond the specifications. Custom software to speed your measurement tasks can be fully integrated inside the oscilloscope application for seamless operation. Hardware acceleration aids measurement speeds and throughput. And our RF and probing experts have ensured that you get the most accurate measurements every time with less scope noise to interfere and probes that operate to the full bandwidth of the scope.

Superior Oscilloscope Signal Integrity

  • 13 GHz bandwidth.
  • 40 GSa/s on each of 4 analog channels
  • Standard 20 Mpts memory per channel, upgradeable to industry leading 1 Gpts

Engineered for Unmatched Real-Time Measurement Accuracy

  • Industry''s lowest noise floor at 3.37 mV at 100mV/div
  • Deepest jitter analysis capability (PRBS^23) and most accurate real-time Tj and Rj characterization for data rates at 8.5 Gb/s and below
  • Hardware accelerated de-embedding allows easy compensation for probe, fixture, and channel effects. Get more details

Pass Today''s Demanding Compliance Tests More Quickly

  • Over 30 software applications for compliance, debugging and analysis including: SATA 6G, PCI EXPRESS® II, HDMI, Ethernet, DDR, etc. Compliance applications
  • Our industry experts in key standards organizations ensure that our tools include the right measurements every time.
  • Predefined test suites and complete reports mean technicians can execute tests thus freeing valuable engineering resources.

Debug Your Toughest Designs with Confidence

  • New User Defined Application allows for rapid automation of any scope measurement. Find and share user defined applications at Agilent Discussion Forum.
  • Customize your Infiniium oscilloscope using User Defined Functions, User Defined Application, and My Infiniium for more efficient operation. Find and share customization examples at Agilent Discussion Forum.
  • MATLAB® software available directly from Agilent for making your own custom measurement and analysis routines, user-defined filters, or instrument applications. MATLAB software for Agilent oscilloscopes
List of Options
002 EZJIT jitter analysis Software - installed
003 High-Speed SDA and Clock Recovery - installed
004 EZJIT Plus jitter analysis software-installed
005 Noise reduction and BW control-installed
006 MyInfiniium customization tool - installed
007 Low-Speed SDA - installed
008 CAN Serial Data Analysis - installed
009 InfiniiScan - installed
010 User-Defined Function - installed
011 App Remote Programming Interface - installed
01G 1G Memory / CH Upgrade
01G 1G Memory / CH Upgrade
021 Ethernet compliance application - installed
022 PCI EXPRESS compliance application - installed
023 HDMI compliance application - installed
024 FB-DIMM compliance application - installed
025 Fibre Channel compliance - installed
026 Serial ATA compliance application - installed
027 SAS compliance application - installed
028 DisplayPort compliance application - installed
029 USB2.0 compliance application - installed
030 XAUI compliance application - installed
031 DDR1 compliance application - installed
032 DDR2 compliance application - installed
033 DDR3 compliance application - installed
034 DVI compliance application - installed
100 100M Memory / CH Upgrade
100 100M Memory / CH Upgrade
200 200M Memory / CH Upgrade
200 200M Memory / CH Upgrade
20M 20M Memory / CH Upgrade
500 500M Memory / CH Upgrade
500 500M Memory / CH Upgrade
50M 50M Memory / CH Upgrade
50M 50M Memory / CH Upgrade
800 Standard Hard Drive
801 Removable Hard Drive
803 Additional PC memory - 4GB
805 GPIB Card-Interface
A6J ANSI Z540 Compliant Calibration
DSO90000-1A7 ISO 17025 Cal Certificate
DSO90000-A6J ANSI Z540 Compliant Calibration
DSO90000-DST Demo SW license
DSO90000A-002 EZJIT jitter analysis Software - installed
DSO90000A-003 High-Speed SDA and Clock Recovery - installed
DSO90000A-004 EZJIT Plus jitter analysis software - installed
DSO90000A-007 I2C/SPI Protocol Triggering and Decode - installed
DSO90000A-008 CAN, LIN, FlexRay Protocol Triggering and Decode - installed
DSO90000A-009 InfiniiScan - installed
DSO90000A-010 User-Defined Function - installed
DSO90000A-011 App Remote Programming Interface - installed
DSO90000A-012 Infiniium Signal Equalization - installed
DSO90000A-013 InfniiSim Basic - installed
DSO90000A-014 InfiniiSim Advanced - installed
DSO90000A-015 RS-232/UART Protocol Triggering and Decode - installed
DSO90000A-016 USB 2.0 Protocol Triggering and Decode - installed
DSO90000A-017 PCI e 1.1 Protocol Triggering and Decode - installed
DSO90000A-018 SAS/SATA Protocol triggering and Decode - installed
DSO90000A-019 MIPI D-Phy Protocol Triggering and Decode - installed
DSO90000A-01G Memory / CH Upgrade, 1 GHz - installed
DSO90000A-021 Ethernet compliance application - installed
DSO90000A-022 PCI EXPRESS compliance application - installed
DSO90000A-023 HDMI compliance application - installed
DSO90000A-024 FB-DIMM compliance application - installed
DSO90000A-025 Fibre Channel compliance - installed
DSO90000A-027 SAS compliance application - installed
DSO90000A-028 DisplayPort compliance application - installed
DSO90000A-029 USB2.0 compliance application - installed
DSO90000A-030 XAUI compliance application - installed
DSO90000A-031 DDR1 compliance application - installed
DSO90000A-032 DDR2 compliance application - installed
DSO90000A-033 DDR3 compliance application - installed
DSO90000A-034 DVI compliance application - installed
DSO90000A-035 MIPI D-PHY compliance application - installed
DSO90000A-036 Automated Test Application, 10GBASE-T - installed
DSO90000A-038 SATA 6Gb/s Compliance - installed
DSO90000A-040 User Defined Application - installed
DSO90000A-041 USB 3.0 Compliance Software - installed
DSO90000A-042 JTAG Protocol Decode - installed
DSO90000A-043 SAS-2 Compliance Test Software – Installed
DSO90000A-044 PCI Express compliance application for PCIe 1.0, 1.1 ,2.0 and 3.0
DSO90000A-061 MATLAB - Basic Digital Analysis Package
DSO90000A-062 MATLAB - Standard Digital Analysis Package
DSO90000A-100 Memory / CH Upgrade 100M- installed
DSO90000A-1CM Rack Mount Kit
DSO90000A-200 Memory / CH Upgrade 200M- installed
DSO90000A-500 Memory / CH Upgrade 500M- installed
DSO90000A-50M Memory / CH Upgrade 50M- installed
DSO90000A-800 Standard Hard Drive - installed
DSO90000A-801 Removable Hard Drive - installed
DSO90000A-805 GPIB Card-Interface - installed
DSO90000A-807 Adapter -1 Mohm, with a 500 MHz passive probe
DSO90000A-820 DVD-RW drive
DSO90000A-821 Additional Precision BNC to SMA adapters includes qty 2
DSO90000A-822 External Touchscreen Monitor For Infiniium
DSO90000A-823 PCI Express Cards - Installed
R-50C-011-3 Agilent Calibration - 3 years
R-50C-011-5 Agilent Calibration - 5 years
R-50C-016-3 ISO 17025 Compliant Calibration - 3 years
R-50C-016-5 ISO 17025 Compliant Calibration - 5 years
R-50C-021-3 ANSI Z540-1-1994 Calibration - 3 years
R-50C-021-5 ANSI Z540-1-1994 Calibration - 5 years
R-51B-001-3C Return to Agilent Warranty - 3 years
R-51B-001-5C Return to Agilent Warranty - 5 years
R-51B-001-C Return to Agilent Warranty - 1 year
W10 Windows 10 Operating System
W7X Windows 7 Operating System
WXP Windows XP Operating System
Specifications & Attributes (Oscilloscopes)
Form Factor
Benchtop
Bandwidth
500 MHz ( /DSO90000A-807 )
1 GHz ( /DSO90000A-01G )
13 Ghz
Channels
4 Ch
Sample Rate
40 GSa/s
Type
Digital
Digital Storage (DSO)

Request a Quote