Description
The HP/Agilent 83550A is an RF plug-in for the 8350B sweep oscillator mainframe that extends microwave testing capabilities across 8.0 GHz to 20.0 GHz. This unit delivers leveled output power exceeding +20 dBm from 8.0 GHz to 18.6 GHz, dropping to +18 dBm minimum in the 18.6–20.0 GHz band. Output level accuracy is ±1.5 dB with frequency accuracy of ±20 MHz.
Specifications:
Frequency Range: 8.0 GHz to 20.0 GHz
Output Leveled Power: >+20 dBm (8.0–18.6 GHz); >+18 dBm (18.6–20.0 GHz)
Output Level Accuracy: ±1.5 dB
Frequency Accuracy: ±20 MHz
Harmonic Spurious Signals: –20 dBc at maximum specified power
Non-Harmonic Spurious Signals: –50 dBc at maximum specified power
Output Connector: N(f)
List of Options
| 002 |
70 dB Attenuator |
| 004 |
Rear Panel RF Output |
| 006 |
Rear auxiliary output |
| 1BN |
Military Standard 45662A Calibration Certification |
| 1BP |
Military Standard 45662A Calibration with Test Data |
| 910 |
Additional operating and service manual |
| UK6 |
Commercial calibration with test results data |