| 100 |
Freq range 10MHz to 10GHz |
| 1BN |
Military Standard 45662A Calibration Certification |
| 910 |
Additional operating and service manual |
| H09 |
10 MHz to 10 GHz with 900 MHz-1300 MHz data in 50 MHz steps |
| H13 |
100kHz to 1GHz, max VSWR 1.8 to 300kHz, 1.3 to 1GHz Calibrated at 100, 300, 500 kHz 1,3,5,10,30,50,100,300,500, and 1000 MHz |
| H42 |
STDS LAB CAL AT 100 MHZ |
| H55 |
Frequency range from 1MHz to 1GHz; Operates with 432A ONLY (US Ref) Frequency range: 1 MHz to 1 GHz SWR: 1.3 MAX. |
| H57 |
Standards lab cal at 30 MHz, 1, 5, 8.2, 10 GHz |
| H63 |
100 KHz to 1 GHz OPERATION (usable with 432A/B/C ONLY); Cal.Data not included FREQ. RANGE: 100 KHz TO 1 GHz MAX. VSWR: 300 KHz TO 1 GHz = 1.3
|
| H72 |
Frequency Range 1 MHz- 1 GHz VSWR 1.1 1 -100 MHz; 1.2 100- 1000 MHz |
| H73 |
Coaxial thermistor mount, 1-100 MHz, VSWR 1.05 at 50 MHZ, 1.1 1-100 MHz |
| H75 |
Frequency Range 1 MHz - 1 GHz SWR 1.3 Max, 1.05 @ 50 MHz |
| H76 |
Frequency Range 1 MHz - 1 GHz; SWR 1.3 Max, 1.05 @ 50 MHz; Primary Standard Calibration @ 50 MHz |
| H78 |
Standards Lab Calibration |
| H81 |
STANDARDS LAB. CAL. 0.1,0.3,0.5, 1, 1.5, AND 2 GHZ |
| H83 |
1 MHz to 1 GHz. Max SWR 1.3 except at 50 MHz max SWR of 1.05 with Std Lab cal The 478A-H83 is an 478A-H75 that gets a standards lab calibration at |
| H84 |
STDS LAB CAL at Freq's specified in the detail description (12 pts) Standards Lab. Cal for Cal. Factor, Cal. Factor Uncertainty, and RHO Data at |
| H88 |
MODIF .1MHZ-1GHZ OPER.;MAX SWR 1.3;EXCEPT 1.05 @30,50,100MHZ;STD CAL DATA |
| H89 |
Mod. for 1MHz-1000MHz Range ONLY; SWR MAX 1.05, 10-100MHz; 10,50,100MHz Cal |
| H90 |
SAME AS STD UNIT PLUS LAB CALIBRATION AT 11, 12, 12.4 GHZ |
| H91 |
50MHz - 90 MHZ OPERATION ONLY, SWR 1.1, AND STANDARD LAB CAL AT 70 MHZ |
| H92 |
RANGES: 1MHZ-1GHZ; 95-100% CAL.FACTOR; 1UW-10MW; MAX VSWR STEPS; W/OPT 9 |
| H93 |
Freq range 1MHz to 1GHz, max SWR 1.3 except 1.05 at 50MHz. Std lab cal at 50MHz and 100MHz |
| H94 |
MODIFIED FOR 1MHz-1GHz Oper.;1.05 SWR (50MHz);W/Stds Data 30,50,100,1000 MODIFIED FOR 1 MHz TO 1 GHz OPERATION. MAXIMUM SWR 1.3 EXCEPT AT 50 MHz |
| H95 |
Freq range 1MHz - 1000 MHz; measures PWR level of 1uW TO 10mW |
| K92 |
STANDARDS LAB CAL AT 11, 12, 12.4 GHZ |
| K96 |
Standards Lab Cal at 50MHz *** see H76 ***** |
| R-50C-011-3 |
Agilent Calibration - 3 years |
| R-50C-011-5 |
Agilent Calibration - 5 years |
| R-50C-021-3 |
ANSI Z540-1-1994 Calibration - 3 years |
| R-50C-021-5 |
ANSI Z540-1-1994 Calibration - 5 years |
| R-51B-001-3C |
Return to Agilent Warranty - 3 years |
| R-51B-001-5C |
Return to Agilent Warranty - 5 years |
| R-51B-001-C |
Return to Agilent Warranty - 1 year |