Keysight (Agilent) N8481A

Thermocouple Power Sensors - 10 MHz to 18 GHz
Contact us for pricing and availability.
Description
N8480 Series Power Sensors are the replacement solutions for 8480 Series Power Sensors. The new power sensors are integrated with EEPROM feature, which allows users to calibrate the power sensors without manually entering the calibration factors to the power meter. By comparing to legacy 8480 Series Power Sensors, there are tremendous improvements such as wider dynamic range and frequency range, better accuracy, linearity, repeatability, and SWR.

Features:
  • EEPROM to store cal factors eliminates manual entry
  • Wide frequency range from 10 MHz to 18 GHz
  • Wide dynamic range from -35 dBm to +20 dBm
  • Best-in-class power linearity of less than 1%, excellent SWR of mismatch uncertainty and highly accurate power repeatability
  • Accurate calibration and traceability to US National Institute of Standards and Technology (NIST)
  • SCPI codes compatible with 8480 series (option CFT)
Note: Option CFT is available as a replacement of legacy 8480 Series power sensors intended for cal factor manual entry and SCPI compatibility. Option CFT is not compatible with 43x and other obsolete power meters.

  • SCPI codes compatible with E-Series sensor (standard option)
  • Compatible with EPM (new N1913/14A, E4418/19B), EPM-P (E4416/17A), P-Series (N1911/12A) power meters (Firmware upgrade required)
Note: All N8480 series power sensors are not compatible with the Agilent 43x, E1416A, N8262A power meters, 5314x microwave counters and E7495x base station test set.
List of Options
100 Type N (m) connector
11730A Power Sensor and SNS Noise Source Cable (1.5m / 5 feet)
11730B Power Sensor and SNS Noise Source Cables (3 m/10 feet)
11730C Power Sensor and SNS Noise Source Cable (6.1m/20 feet)
11730D Power Sensor Cable (15.2m/50 feet)
11730E Power Sensor Cable, (30.5m/100 feet)
1A7 Certificate of compliance calibration - ISO 17025 with test data, printed
200 APC-7 connector
A6J Certificate of compliance calibration - ANSI Z540 with test data, printed
CFT Cal Factor Option, -30dBm to +20dBm
R-50C-011-3 Agilent Calibration - 3 years
R-50C-011-5 Agilent Calibration - 5 years
R-50C-016-3 ISO 17025 Compliant Calibration - 3 years
R-50C-016-5 ISO 17025 Compliant Calibration - 5 years
R-50C-021-3 ANSI Z540-1-1994 Calibration - 3 years
R-50C-021-5 ANSI Z540-1-1994 Calibration - 5 years
R-51B-001-3C Return to Agilent Warranty - 3 years
R-51B-001-5C Return to Agilent Warranty - 5 years
R-51B-001-C Return to Agilent Warranty - 1 year
STD Standard Option, -35dBm to +20dBm
Specifications & Attributes (Power Sensor)
Form Factor
Benchtop
Frequency Range
10 MHz - 18 GHz

Request a Quote