Keysight (Agilent) 66319D

DC Power Supply, 15 V/3 A, 45 W; 12 V/1.5 A, 18 W; Dual Output, Programmable
Contact us for pricing and availability.
Description
The Agilent Mobile Communications DC Source 663xx series offers several features ideal for testing wireless and battery powered devices. Excellent voltage transient response ensures maximum test-system throughput by minimizing device shutdowns due to significant voltage drops in the test wiring. Built-in advanced measurement system to accurately measure battery current drains when the device operates in different modes and an Agilent-developed feature that enables cellular telephone manufacturers to detect permanently and intermittently open-sense wire connections.

The Agilent 66319D dual output mobile communications dc source provides two outputs for testing both the main battery power and the battery charger circuitry, allowing customers to test phones and chargers with the same equipment. This feature helps save on rack space (2 outputs in a ½ rack box) and eliminates the need for two separate power supplies. The 66319D dc source provides all of the capabilities of the 66319B with the addition of a built-in digital voltmeter.

For R&D engineers, you can characterize current out of the battery and make tradeoffs in design that impact the current drain and battery life (by providing data logging – up to 1000 hours, CCDF statistical analysis, and waveform capture) , when the 66319B is used with the Agilent 14565B Software.

Output Ratings

  • Voltage: 0 to 15 V
  • Current: 0 to 3 A
  • Peak Current for up to 7 ms: 5 A

Programming accuracy at 25°C ±5°C (% of setting plus fixed)

  • Voltage: 0.05% + 10 mV
  • +Current: 0.05% + 1.33 mA

DC Readback Accuracy

  • Voltage: 0.03% + 5 mV
  • Current (-3 A to + 5 A): 0.2% + 0.5 mA
  • Current (-1 A to + 1 A): 0.1% + 0.2mA
  • Current (-20 mA to + 20 mA): 0.1% + 2.5 µA

Transient Response

  • 40 mV drop, <20 µs transient response time
List of Options
007 2 Extra 5-pin output connectors
053 Add battery drain analyzer and software
0B0 Do not include manuals
0L1 English Printed Users Guide (full documentation on CD-ROM)
0L2 Additional standard documentation package
100 87-106VAC operation, 50/60Hz
120 104-127VAC operation, 50/60Hz
14565A DEVICE CHARCTERIZATION SW & DOC
14565B Device Characterization Software with Test Automation
14565U Device Characterization Software Upgrade
1CM Rackmount Kit with blank filler panel
220 191-233VAC operation, 50/60Hz
230 209-254VAC operation, 50/60Hz
521 Add solid state output disconnect relays
8ZJ Delete Feet
8ZL Add feet ( 4 x p/n 5041-8801)
A6J Certificate of calibration - ANSI/NCSL Z540, printed
AXS Rackmount Kit for side by side mounting
AYK No solid state output disconnect relays (standard)
R-50C-011-3 Agilent Calibration - 3 years
R-50C-011-5 Agilent Calibration - 5 years
R-50C-016-3 ISO 17025 Compliant Calibration - 3 years
R-50C-016-5 ISO 17025 Compliant Calibration - 5 years
R-50C-021-3 ANSI Z540-1-1994 Calibration - 3 years
R-50C-021-5 ANSI Z540-1-1994 Calibration - 5 years
R-51B-001-3C Return to Agilent Warranty - 3 years
R-51B-001-5C Return to Agilent Warranty - 5 years
R-51B-001-C Return to Agilent Warranty - 1 year
RMKT Agilent Refurbished Product (Do Not Use - Certiprime Option)
UK6 Commercial calibration certificate with test data included
Specifications & Attributes (DC Power Supplies)
Form Factor
Benchtop
Rackmount ( /1CM )
Connectivity
GPIB
Current
1.5 A
3 A
Power
18 W
45 W
Type
CV/CC
Voltage
12 V
15 V