Description
The Narda 8511 is intended primarily for industrial applications and is very easy to operate. This measuring device has fixed, isotropic probes and can measure E and H fields without changing probes.
Features:
Complete Measurement System (Meter with dual sensor probe which measures Electric and Magnetic Fields independent)
Extremely easy to use
High overload Tolerance
RMS Detection
Isotropic Probes
Auto Zero
Specifications:
Frequency range 300 kHz to 100 MHz
Band coverage 0.3 - 1.0 MHz, 1.0 - 20 MHz
20 - 80 MHz, 80 - 100 MHz
Measurement range 0.1 bis 100 mW/cm² E field
0.2 bis 200 mW/cm² H field
Special feature(s) Zero alignment at a keypress
Display units mW/cm², W/m², V/m, A/m