0-B15 |
Extension board only for SFE100 model.02 S/N > 121000 only for SFE100 model.03 S/N > 131000 |
0A-C5 |
Five years of calibration coverage based on the R&S recommended calibration interval - includes test data. |
0A-R3 |
Three years of depot repair coverage, including recalibration and test data if necessary to complete the repair. |
0A-R5 |
Five years of depot repair coverage, including re-calibration if necessary to complete the repair. |
0DKD |
SMU200A DKD (ISO17025) calibration incl. ISO9000 calibration (order only with device) |
B1 |
Pre-amplifier mount |
B10 |
Baseband generator with dig. modulation (real time) and ARB (64 M samples) SMU-B13 req. (factory-fitted) |
B102 |
Frequency range 100 kHz - 2.2 GHz for 1st RF path (factory fit only) |
B103 |
Frequency range 100 kHz - 3GHz for 1st RF path (factory fit only) |
B104 |
Frequency range 100 kHz - 4 GHz for 1st RF path (factory fit only) |
B106 |
Frequency range 100 kHz - 6 GHz for 1st RF path (factory fit only) |
B10x2 |
Baseband generator with dig. modulation (real time) and ARB (64 M samples) SMU-B13 req. (factory-fitted) / Path 1 and 2 |
B11 |
Baseband generator with digital mod. (real time) and ARB (16 M samples) SMU-B13 required (factory fitted) |
B13 |
Baseband Main Module (Factory fitted only) |
B13X2 |
Baseband main module RF path 1 and 2 |
B14 |
Fading simulator (required: SMU-B13(factory-fitted) and SMU-B9/B10/B11) |
B15 |
Fading simulator extension SMU-B14 required (factory-fitted) |
B16 |
Differential I/Q outputs (SMU-B13(factory-fitted) required) |
B17 |
Analog/Digital Baseband Inputs (required: SMU-B13(factory-fitted) and SMU-B9/B10/B11) |
B18 |
Digital Baseband Output according to R&S Standard TVR290 (SMU-B13[factory-fitted] required) |
B2 |
Fixture, Tripod Mount |
B20 |
FM/PHIM modulator (SMU-B10X(factory-fitted) required) |
B202 |
Frequency range 100 kHz - 2.2 GHz for 2nd RF path (factory fit only) |
B203 |
Frequency range 100 kHz - 3 GHz for 2nd RF path (factory fit only) |
B22 |
FM/PHIM modulator and enhanced phase noise performance (SMU-B10X(factory-fitted) required) |
B24 |
Internal preamplifier 100kHz to 40GHz; gain 30dB nominal |
B3 |
TS-PR TEFLON NON-REFLECTIVE TRIPOD/MAST COMBO MOUNTING ASSEMBLY |
B30 |
OVERVOLTAGE PROTECTION RF PATH A |
B31 |
High power output for 1st RF path (factory fitted) (for SMU200A with serial number |
B32 |
Overvoltage protection and high power for 1st RF path not SMU-B104/B106(factory fit) |
B35 |
Overvoltage protection for 2nd RF path; not for (factory-fitted) |
B36 |
High power output for 2nd RF path (factory fitted) (For SMU200A with serial number |
B4 |
TS-PR 31 17 horn antenna with 1 & 3 meter horizontal and vertical calibration data (for TS-PR3, TS-PR8 & TS-PR18 ONLY) |
B5 |
TS-PR 3160-9 horn antenna with 1 meter horizontal & vertical calibration data (for TS-PR26 only) |
B6 |
TS-PR 3160-10 horn antenna with 1 meter horizontal & vertical calibration data (for TS-PR40 only) |
B7 |
TS-PR 8 meter low loss ruggedized RF cable (N type connectors for use up to 18 GHz) |
B81 |
Rear panel connectors for 1st RF path (factory-fitted only) |
B82 |
Rear panel connectors for 2nd RF path (factory-fitted only) |
B9 |
Basebandgenerator with dig. modulation (real time) and ARB (128 M Samples) (factory fitted, SMU-B13 required) |
B90 |
Phase Coherence (factory fitted |
C3 |
Three years of depot calibration coverage based on the R&S recommended calibration interval - includes test data. The first calibration is included with product delivery with 2 additional depot calibration(s). |
C5 |
Five years of calibration coverage based on the R&S recommended calibration interval - includes test data. The first calibration is included with product delivery with 1 additional depot calibration(s). |
DCV-2 |
Documentation of calibration values |
DCV-ZP |
Printout of DCV (additional, in combination with DCV-Option only) |
EX-IQ-BOX |
Digital I/O adapter module for AFQ, AMU, FMU, FSG, FSQ, SMJ, SMU (AFQ-B18, AMU-B17, AMU-B18, FSQ-B17, |
K1 |
Digital I/Q Interface Option for TSMW for IQ streaming via Gigabit LAN; MatLab and C++ based. |
K12 |
CDMA 1x EVDO Option for TSMU IS-95 and CDMA2000 1xEVDO Rev. A all bands; |
K14 |
WCDMA BCH Demodulator Option for TSMU all bands, requires TSMU-K11. |
K15 |
CW RF Power Measurement Option for TSMU 80 - 3000 MHz, Single or Mult. Channel; Time or distance trigger. |
K17 |
Spectrum Measurement Option for TSMU RF Power Scan 80 - 3000 MHz, single or multi channel. |
K19 |
802.11A,B,G (REQ B10,B13) |
K20 |
3GPP FDD W/HSDPA |
K21 |
GSM & WCDMA Option for TSMW WCDMA PN scanner option incl. BCH demodulator |
K240 |
Digital standard GSM/EDGE. (SMU-B9/B10/B11 + WinIQSIM 2 required) |
K241 |
Digitaler standard EDGE evolution (SMU-K240 and external PC software |
K242 |
Digital standard 3GPP FDD. (SMU-B9/B10/B11 + WinIQSIM 2 required) |
K243 |
3GPP FDD enhanced MS/BS tests incl. HSDPA. (SMU-B9/B10/B11, SMU-K242 and |
K244 |
Digital standard GPS (SMU-B9/10/11 and WINIQSIM 2 required) |
K245 |
Digital standard HSUPA. |
K246 |
Digital standard CDMA2000 incl. 1xEV-DV. (SMU-B9/B10/B11 + WinIQSIM 2 required) |
K247 |
Digital Standard 1XEV-DO REV.A (SMU-B9/10/11 required, WINIQSIM required) |
K248 |
Digital standard IEEE 802.11 (a/b/g). (SMU-B9/B10/B11 + WinIQSIM 2 required) |
K249 |
Digital standard IEEE 802.16 (SMU-B9/B10/B11 + WinIQSIM 2 required) |
K250 |
Digital standard TD-SCDMA. (SMU-B9/B10/B11 + WinIQSIM 2 required) |
K251 |
Digital standard TD-SCDMA enhanced features. (SMU-B9/B10/B11, SMU-K250 and |
K252 |
ption: Digital Standard DVB-H (SMU-B9/10/11 required, WINIQSIM 2 required) |
K254 |
Digital Standard IEEE 802.11n (SMU-B9/B10/B11 required, WINIQSIM 2 required) |
K255 |
Digital Standard EUTRA (SMU-B9/10/11 + WINIQSIM 2 required) |
K256 |
Playback of XM Radio waveforms (license and waveforms from XM Radio required, |
K259 |
Digital standard HSPA+ (SMU-B9/B10/B11, SMU-K243/K245 and ext. PC software WinIQSIM2 required) |
K260 |
Digital standard Bluetooth Enhanced Data Rate (SMU-B9/B10/B11 and external PC software |
K261 |
Multicarrier CW signal generation (SMU-B9/B10/B11 and WinIQSIM 2 required) |
K262 |
Additive white Gaussian noise (SMU-B9/10/11 + WinIQSIM2 required) |
K28 |
WiMAX Option for TSMW all IEEE802.16e bands requires ROMES4T1W |
K29 |
LTE Option for TSMW requires ROMES4T1W |
K352 |
HD Radio test waveforms. Ibiquity license for customer required (SMU-B9/B10 required) |
K40 |
Digital standard GSM/EDGE (SMU-B9/B10/B11 required) |
K40x2 |
Digital standard GSM/EDGE (SMU-B9/B10/B11 required) / Path 1 and 2 |
K41 |
Digital standard EDGE evolution (SMU-K40 required) |
K41x2 |
Digital standard EDGE evolution (SMU-K40 required) / Path 1 and 2 |
K42 |
Digital standard 3GPP FDD (SMU-B9/B10/B11 required) |
K42x2 |
Digital standard 3GPP FDD (SMU-B9/B10/B11 required) / Path 1 and 2 |
K43 |
3GPP FDD enhanced MS/BS tests incl. HSDPA (SMU-K42 required) |
K43x2 |
3GPP FDD enhanced MS/BS tests incl. HSDPA (SMU-K42 required) / Path 1 and 2 |
K44 |
Digital standard GPS (SMU-B9/B10/B11 required) |
K44x2 |
Digital standard GPS (SMU-B9/B10/B11 required) / Path 1 and 2 |
K45 |
3GPP FDD HSUPA; (SMU-B9/B10/B11 and SMU-K42 required) |
K45x2 |
3GPP FDD HSUPA; (SMU-B9/B10/B11 and SMU-K42 required) / Path 1 and 2 |
K46 |
Digital standard CDMA2000 incl. 1xEV-DV (SMU-B9/B10/B11 required) |
K47 |
Option:Digital Drandard 1XEV-DO REV.A (SMU-B9/b10/B11 required) |
K48 |
Digital standard IEEE 802.11 (a/b/g) (SMU-B9/B10/B11 required) |
K49 |
Digital standard IEEE 802.16 (SMU-B9/B10/B11 required) |
K5 |
Dig. Std. Bluetooth external PC software SMU-B10/B11 required |
K50 |
Digital standard TD-SCDMA. (SMU-B9/B10/B11 required) |
K51 |
TD-SCDMA enhanced MS/BS tests. (SMU-B9/B10/B11 and SMU-K50 required) |
K52 |
Digital standard DVB-H / DVB-T (SMU-B9/B10/B11 required) |
K53 |
Digital Standard DAB/T-DMB (SMU-B9/B10/B11 required) |
K54 |
Digital Standard IEEE 802.11n (SMU-B9/B10/B11 required) |
K55 |
Digital standard LTE/EUTRA (SMU-B9/B10/B11 required) |
K55x2 |
Digital standard LTE/EUTRA (SMU-B9/B10/B11 required) / Path 1 and 2 |
K56 |
Digital standard XM Radio (SMU-B9/B10/B11 required) |
K57 |
FM stereo modulation (SMU-B9/B10/B11 required) |
K58 |
Sirius Digital Radio. Generation of 1 carrier in real time (SMUB9/B10/B11 required, SMU-B9 |
K59 |
Digital standard HSPA+ (SMU-B9/B10/B11 + SMU-K43/K45 required) |
K59x2 |
Digital standard HSPA+ (SMU-B9/B10/B11 + SMU-K43/K45 required) / Path 1 and 2 |
K6 |
Pulse Sequencer; external PC-Software (SMU-B9/B10/B11 required) |
K60 |
Digital standard Bluetooth Enhanced Data Rate (SMU-B9/B10/B11 required) |
K61 |
Option:Multicarrier CW signal generation (SMU-B9/B10/11 required) |
K62 |
Additional white gaussian noise (SMU-B13(factory-fitted) required) |
K65 |
Assisted GPS (2xSMU-B9/B10/B11 + 2xSMU-K44 required) |
K68 |
Digital standard TETRA Release 2 (SMU-B9/B10/B11 required) |
K69 |
LTE Closed-Loop BS Test HARQ Feedback, Timing Adjustment (SMU-K55 required) |
K71 |
Dynamic fading and enhanced resolution (SMU-B14 required) |
K72 |
Enhanced fading models (SMU-B14 required) |
K74 |
MIMO Fading (SMU-B14 and SMU-B15 as well as two Baseband Sources SMU-B9/B10/B11 req.) |
K8 |
TETRA software for SMU200A (SMU-B9/B10/B11 required) |
K80 |
Bit error rate tester |
K81 |
LTE Logfile generation. Intermediate results and logfiles of the LTE signal generation process |
R3 |
Three years of depot repair coverage, including recalibration and test data if necessary to complete the repair. First year of repair coverage is provided by the 12-month new product warranty. |
R5 |
Five years of depot repair coverage, including re-calibration if necessary to complete the repair. First year of repair coverage is provided by the 12-month new product warranty. |
SMU200DKD |
SMU200A DKD (ISO17025) calibration incl. ISO9000 calibration (order only with device) |
SMV03-DKD |
SMV03 DKD (ISO17025) calibration incl. ISO 9000 calibration (order only with device) |
TH |
TSMU-H Scanner for Mobile RF Networks for ROMES Drive Test Systems; 12 VDC power supply; |
TK11 |
WCDMA Option for TSMU all bands. |
TK13 |
GSM Option for TSMU all bands. |
TS-55CONN |
GM TS-55CONN CONNECTION BOX |
TS-CBXRRM |
4:1 Combiner for RRM and InterRAT systems 0.3 GHz - 3 GHz, 6 dB loss |
TS-CRRM1 |
LVD CABLE SET FOR CONNECTING RRM WITH 1 EXTERNAL CRTU-W TO TS8950W |
TS-CRRM2 |
LVD CABLE SET FOR CONNECTING RRM WITH 1 EXTERNAL CRTU-W AND 1 EXTERNAL CRTU-G TO TS8950W |
TS-CRRM3 |
LVD CABLE SET FOR CONNECTING RRM IN A TS8950W WITH TWO INTERNAL (RACK-MOUNTED) CRTU-W |
TS-CRRM4 |
LVD CABLE SET FOR CONNECTING RRM WITH 1 EXTERNAL CRTU-G IN A TS8950W WITH TWO INTERNAL (RACK-MOUNTED) CRTU-W |
TS-CRRM5 |
LVD CABLE SET FOR CONNECTING RRM IN A TS8950GW WITH TWO INTERNAL CRTU-W AND 1 INTERNAL CRTU-G |
TS-CRRM6 |
LVD CABLE SET FOR CONNECTING RRM IN A TS8950GW WITH 1 INTERNAL CRTU-W AND 1 INTERNAL CRTU-G AND 1 EXTERNAL CRTU-W |
TS-EMF |
Isotropic Antenna 30 MHz - 3 GHz for use with Spectrum Analyzer FSH |
TS-EMFZ2 |
Cable set for TS-EMF |
TS-EX-IQ2 |
Baseband digital combiner unit BS & MS |
TS-F1A |
SHIELDED FIXTURE WITHOUT FITTINGS |
TS-F1A1 |
ACOUSTICS KIT FOR FIXTURE |
TS-F1C1 |
FIXTURE CABLING: USB, RS232, PSU, AUDIO |
TS-F1I1 |
ADAPTER INTERFACE FOR USB UND TS-PRL1 |
TS-F1MA1 |
MOUNTING KIT FOR ACOUSTIC KIT AND UNIVERSAL DUT HOLD-DOWN |
TS-F1N1 |
UNIVERSAL ANTENNA COUPLER 770-960MHZ/ 17 |
TS-F1P1 |
DUT HOLDER PLATES |
TS-F1P1UN |
DUT HOLDER PLATE FOR RF FIXTURE FULLY MOUNTED, W: SELF ADHESIVE SPONGE, W/O VG CONNECTOR |
TS-F1P2 |
HOLD DOWN PLATE FOR RF FIXTURE (NOT CUSTOMIZED) |
TS-F1PNE4 |
PNEUMATIC 4x KIT FOR TS-F1P1 AND TS-F1P2 |
TS-F1PNE8 |
PNEUMATIC KIT 8 X FOR TS-F1P1 AND TS-F1P2 |
TS-F21AB1 |
Absorber kit for elevated cover |
TS-F21ABS |
Absorber kit for TS7121 |
TS-F21AGB |
Antenna coupler for TS7121: GSM,CDMA2000 2 inputs - GSM, etc.: 770 - 900 MHz and 1.7 - 2.2 |
TS-F21FU2 |
USB filter feedthrough for TS7121 - Feedthroug filter USB 1.1 and 2.0 - Exchangeable connector plate |
TS-F23A-G |
Absorber and antenna coupler GSM, CDMA20 for TS7123 - Antenna coupler |
TS-F23AB1 |
Absorber kit for elevated cover |
TS-F23ABS |
Absorber kit for TS7123 |
TS-F23EC1 |
Elevated cover for TS7123 height: 160 mm (without absorber) |
TS-F23FU2 |
USB filter feedthrough for TS7123 - Feedthroug filter USB 1.1 and 2.0 - Exchangeable connector plate |
TS-F2X-B2 |
Bluetooth antenna set for TS712x - Bluetooth, WLAN b/g - 2,4 GHz antenna - N connector to SMA RF cable |
TS-F2X-G |
Antenna coupler GSM, CDMA2000, WCDMA for TS7123 and TS7121 (770 - 900 MHz a. 1.7 - 2.2 GHz) |
TS-F2X-I4 |
ISM antenna coupler for TS712x frequency bands (315, 434, 850-950 MHz) - mounting part |
TS-F3F |
OPTION FOR TS-PAD3: FIXTURE-FRAME FOR TEST- FIXTURE |
TS-F3X1 |
OPTION FOR TS-F3F: CONNECTOR CARRIER FOR FEEDTHROUGH, 5 PCS |
TS-FCBV |
FIXTURE CAP FOR INTEGRATION OF CAMERA IN TS7110 |
TS-PR1 |
PREAMPLIFIER 30 MHZ TO 1000 MHZ, gain min. 25 dB, incl., - 115 V POWER SUPPLY, - 0.5 m Antenna Cable, - Ruggedized Shipping Case |
TS-PR18.03 |
TS-PR18; PREAMPLIFIER ANTENNA SYSTEM; 1GHZ - 18 GHz, INCLUDING 115V POWER SUPPLY; 0.5M ANTENNA CABLE AND RUGGEDIZED SHIPPING CASE |
TS-PR26 |
PREAMPLIFIER 18 GHZ TO 26.5 GHZ, gain min. 29 dB, incl., - 115 V POWER SUPPLY, - 0.5 m Antenna Cable, - Ruggedized Shipping Case |
TS-PR3 |
PREAMPLIFIER 30 MHZ TO 3 GHZ, gain min. 25 dB, incl., - 115 V POWER SUPPLY, - 0.5 m Antenna Cable, - Ruggedized Shipping Case |
TS-PR40 |
PREAMPLIFIER 26.5 GHZ TO 40 GHZ, gain min. 50 dB, incl., - 115 V POWER SUPPLY, - 0.5 m Antenna Cable, - Ruggedized Shipping Case |
TS-PR7 |
PREAMPLIFIER 30 MHZ TO 7 GHZ, gain min. 25 dB, incl., - 115 V POWER SUPPLY, - 0.5 m Antenna Cable, - Ruggedized Shipping Case |
TS-PR8 |
PREAMPLIFIER 30 MHZ TO 8 GHZ GAIN MIN 29 DB INCL. - 115 V POWER SUPPLY, 0.5M ANTENNA CABLE, RUGGARIZED SHIPPING CASE |
TS-PRO3 |
PREAMPLIFIER 9 KHZ TO 300 MHZ, gain min. 18 dB, incl., - 115 V POWER SUPPLY, - 0.5 m Antenna Cable, - Ruggedized Shipping Case |
TS-PS24 |
EXTERNAL 24V POWER SUPPLY |
TS-RBRF |
RF-Relay Matrix plug-in module Basic for TS-RSP bis 18 GHz |
TS-REMI |
Plug-in module EMI for TS-RSP |
TS-REMS |
Plug-in module EMS for TS-RSP |
TS-RSP |
Relay switch unit with rear contacts basic unit for plug-in modules |
TS7121A |
RF Test Chamber (WxHxD=155x305x428) - Automatically open and closing drawer (WxD=80x194) |
TS7121M |
RF Test Chamber (WxHxD=155x305x428) - manually opening and closing drawer (WxD=80x194) |
TS7123A |
HF-Test Chamber (WxHxD=330x347x428) - Automatically open and closing drawer (WxD=245x238) |
TS7123M |
HF-Test Chamber (WxHxD=330x347x428) - Manually drawer (WxD=245x238) Window (WxH=252x198-28) |
TS8-KM100 |
CONTEST LTE FDD R&D TX app. package |
TS8-KM110 |
CONTEST R&D RX test application package; permanent license |
TS895RA |
19" system single rack for RRM system 37 HU, fans incl. rack adaptors for NRVS and DPSP |
TS95A16 |
GSM/UMTS/CDMA antenna magnetic mount 850/900/1800/1900/2100 band N-connector |
TS95AUDIO |
2 x audio Unit M-AUDIO Firewire for SQA for R&S® ROMES Drive Test Systems. Model M-Audio firewire high end unit, 24-bit/96kHz converter (ADC/DAC) 2-way, allows voice quality measurements with R&S® ROMES SQA option up to 2 mobiles parallel UL & DL IEE |
TS95LICHL |
USB hardlock for time license server necessary for every client with floating licenses |
TS95UM5 |
UMTS & GSM/GPRS TEST MOBILE "SAMSUNG Z500" BASED ON QUALCOMM CHIPSET MSM6250; UMTS & TRIBAND GSM/GPRS/EDGE (900/1800/1900); CODECS FOR EFR, FR, HR, WCDMA; CLASS 10 |
TSEMF-O3 |
EMC-tripod for TS-EMF |
TSEMF-O5 |
Tripod for TS-EMF |
TSML-C |
CDMA Radio Network Analyzer requires ROMES3T12 for operation with ROMES SW, no antenna included |
TSML-CW |
CW Radio Network Analyzer requires ROMES3T15 for operation with ROMES SW, no antenna included |
TSML-G |
GSM Radio Network Analyzer requires ROMES3T13 for operation with ROMES SW, no antenna included |
TSML-GW |
GSM WCDMA Radio Network Analyzer requires ROMES4T1Q for operation with ROMES SW, no antenna included |
TSML-W |
WCDMA Radio Network Analyzer requires ROMES3T11 for operation with ROMES SW, no antenna included |
TSML-Z1 |
TSMU/Q/L socket power supply input 100 - 240V AC, 47 - 63 Hz 30W |
TSMQ |
TSMQ Quad Tech Drive Test Receiver for ROMES Drive Test Systems; 12 VDC power supply; |
TSMQ-R5 |
Five years of depot repair coverage, including re-calibration if necessary to complete the repair. First year of repair coverage is provided by the 12-month new product warranty |
TSMU |
TSMU Scanner for Mobile RF Networks for ROMES Drive Test Systems; 12 VDC power supply |
TSMW |
TSMW High Performance Scanner 2 Receivers with 20MHz IF BW integrated GPS, 12 V DC |
TSMX-PPS |
GPS Module uBlox for ROMES Drive Test Sy incl. external active uBlox Antenna with PPS-Output, USB-Connector |
TZ1 |
Power Supply 230 VAC 12VDC / 6 A for TSMU / TSMU-H / TSML / TSM-DVB and TSMQ, desktop version |
TZ2 |
Rack Adapter 19" TSMx for TSMU / TSMU-H / TSML / TSM-DVB, 2HU 1 or 2 devices |
TZ3 |
Indoor Back-Pack System for ROMES Drive Test Systems; Frame with accu pack 3000 mAh / 12 V; |
Z1 |
TSMW External Power Supply Input 90 - 260 V AC 47 - 63 Hz, 120 W |
Z5 |
Accessory: BNC adapter for rear panel AUX I/O connector |
Z6 |
Accessory: Cable for connecting digital baseband interfaces of R&S instruments according to TVR290 |
ZZA-411 |
19" adapter, 4 HU, 1/1 for BW2000 cabinets |