Associated Research 7520DT

Hi-Pot / Ground Continuity Testers
Contact us for pricing and availability.
Description
115/230 VAC, 15 %, 47 - 63 Hz, AC Hypot with Ground Continuity Test Set

Features:
  • Input Voltage: 115/230 VAC, ± 15 %, Single Phase, User Selection
  • Input Frequency: 47 - 63 Hz
  • Output Rating:  5 KV @ 20 mA AC
  • Output Adjustment Range: 0 - 5 KV AC
  • Output Adjustment Resolution: 1 volt/step
  • Output Adjustment Accuracy: ± (2% of setting + 5 volts)
  • Ramp-HI: 12 mA peak maximum, ON/OFF selectable
  • Charge-LO Range: 0.0 - 350.0 µA DC or Auto set
  • HI-Limit Range: 0.00 - 20.00 mA
  • HI-Limit Resolution: 0.01 mA/steps
  • HI-Limit Accuracy: ± (2% of setting + 2 counts)
  • LO-Limit Range: 0.000 - 9.999 mA
  • LO-Limit Resolutions: 0.001 mA/steps
  • LO-Limit Accuracy:  ± (2% of setting + 2 counts)
  • Arc Detection Rabge: 1 - 9
  • Failure Detector: Audible and Visual
  • Ground Continuity Current: DC 0.1A ± 0.01A, fixed
  • Ground Continuity Max. Ground Resistance: 1 O ± 0.1 O, fixed
Specifications & Attributes (Hi-Pot / Ground Continuity Testers)