Keysight (Agilent) N5242AS

N5242A Configured for High Power operation
Contact us for pricing and availability.
Description

The Keysight N5241/42AS Option H85 is a modified version of the standard N5241/42A PNA-X Series Network Analyzer. Option H85 is designed to permit insertion of high power amplifiers, and other signal conditioning equipment to allow high power network measurements at RF levels up to 20 Watts (+43 dBm) from 10 MHz to 26.5 GHz. The Option H85 modification supplies extended power range attenuators without bias tees. The N5241/42AS Option 285 (add extended power range to 2-Port analyzer, no bias-tees) replaces the standard N5241/42A Option 219 (add extended power range and bias-tees to 2-Port analyzer). The N5241/42AS Option 485 (add extended power range to 4-Port analyzer, no bias-tees) replaces the standard N5241/42A Option 419 (add extended power range and bias-tees to 4-Port analyzer). The Option H85 does not increase the output power of the N5241/42A analyzer. This option only allows the N5241/42A analyzer to make high power measurements. The user must supply their own amplifier(s) and external components such as high power couplers, attenuators and isolators to configure the analyzer for high power. These components are not supplied, or included with the Option H85. The user is responsible to ensure that these components meet their DUT requirements, and also protect the PNA-X from damage

List of Options
010 Time-domain measurements
014 Configurable Test Set Option (front panel access loops between source output and coupler input) Standard Option
016 Add Reciever Attenuators (35 dB in 5 dB steps)(Standard Option)
020 Add IF inputs
021 Add pulse modulator to internal first source
022 Add pulse modulator to internal second source
025 Add four internal pulse generators
028 Noise figure measurements using standard receivers
029 Fully-corrected noise-figure measurements to 26.5 GHz
080 Add frequency offset mode
081 Reference Channel Switch (Adds internal switch to R1 Path)(Standard Option w/080)
082 Scalar calibrated converter measurements
083 Vector and scalar calibrated converter measurements
084 Embedded LO measurements
086 Add gain compression application
087 Intermodulation distortion measurements
088 Source phase control
219 Add extended power range and bias-tees to 2 port analyzer
485 Add extended power range to 4 port analyzer (no bias-tees)
510 Nonlinear Component Characterization
514 Nonlinear X-Parameters
518 Nonlinear Pulse Envelope Domain
520 Arbitrary load impedance X-parameters
551 N-port calibrated measurements
629 Noise figure accessories
897 Built-in performance test software for Agilent inclusive calibration, perpetual license
898 Built-in performance test software for standards compliant calibration, perpetual license
H08 Pulsed - RF measurments
H85 Removes bias tees between source attenuators and test port couplers
P04 4 Ports Native
S02 Second Source Module
UNL High Power Measurement w/ Bias tees Configuration (Allows Ext. Amplifiers between RF Source and Coupler Input)(Standard Option)

Request a Quote