The NC6000A and NC8000A Series instruments are
designed for general-purpose noise applications on the
bench, or in a rack test station. The manual controls make it
simple to operate and reduce test set up time. The standard
output power NC6000 is typically used for BER, and SNR
applications, while the high power NC8000 is a good
candidate for signal jamming. Each instrument contains a
precision noise source that delivers repeatable, symmetrical
white Gaussian noise and is integrated with an amplifier,
attenuator, and power supply. Noisecom will modify base
units for specific customer needs. For pricing and
availability, consult the factory.
General Specifications
- Output White Gaussian noise
- Attenuator range 0 to 10 dB in 1 dB steps (100 dB in 10 dB steps and 1 dB in 0.1 dB steps optional)
- Impedance 50 Ohms ( 75 Ohms optional)
- Standard connector SMA female (K female for NC6240)
- Dimensions:
- (NC6000) 8.5 in. wide x 5 in. high x 12.25 in. deep
- (NC8000) 17 in. wide x 5.25 in. high x 13 in. deep
- Power requirements are 120 VAC, 60 Hz, at 500 mA for the NC6000, 1500 mA for the NC8000
- Operating temperature -10°to +60°