Keysight (Agilent) MSO8104A

Infiniium Mixed Signal Oscilloscope: 1 GHz, 4 Ch and 16 digital channels 4GSa/s sample rate
Contact us for pricing and availability.
Description
Gain superier insight into analog, digital, or serial design challenges. The Infiniium MS- Windows®-based MSO8104A provides unmatched acquisition performance with up to 128 Mpts of deep memory mapped to a high-definition display, powered by MegaZoom III technology.

Windows is a U.S. registered trademarks of Microsoft Corporation.

1GHz Bandwidth - 4 scope channels - 16 digital channels - 4GSa/s sample rate

  • 8 Mpts standard memory depth with options to 128 Mpts
  • Extensive selection of software applications
  • Connectivity: LAN, USB, GPIB, LXI class C compliant and XGA video
  • See 8000 Series scopes in action - video demo

Analog Signal Viewing

  • XGA color display with 256 levels of intensity
  • Windows based touchscreen with drag and drop measurements
  • Vector Signal Analysis Option

Digital Signal Triggering and Analysis with mixed signal oscilloscope (MSO) models

  • 16 digital channels, time correlated with 4 scope channels
  • Pattern and mixed signal triggering across all analog and digital channels
  • Only integrated FPGA Dynamic Probe Application Options
  • Analog chart of digital bus activity

Serial Decode

  • I2C and SPI decode option
  • CAN serial decode option
List of Options
002 EZJIT jitter analysis software package - installed
003 High-Speed SDA and Clock Recovery for 8000A Series Scopes - installed
006 Application Integration Package - My Infiniium installed
007 Low-Speed SDA - installed
008 CAN SDA - installed
009 InfiniiScan Event Identification Software for 8000 series - installed
010 Infiniium User-Definable Functions via MATLAB Gateway Application Software
017 Removable hard drive for Infiniium 8000 series oscilloscopes
018 Standard hard drive for Infiniium 8000 series oscilloscopes
019 External Touchscreen Monitor For Infiniium
020 DVD-RW drive
040 Memory 4Mpts/Ch, 8Mpts Max
080 Memory Upgrade to 8Mpts/Ch, 16Mpts Max
10073D Probe, Passive 10:1, 500 MHz, 1.5 M
10076B Passive probe, 4KV high-voltage, 100:1, 250 MHz
1130A Probe amplifier, InfiniiMax, 1.5 GHz
1146A Current probe, AC/DC, 100 kHz, 100 A
1147A Current probe with autoprobe, 15A AC/DC, 50MHz
1153A Differential probe with autoprobe, 1X FET, 200 MHz
1156A Active probe, single-ended ,1.5 GHz
1162A Miniature Passive Probe, 1:1, 1.5 m
1165A Miniature Passive Probe, 10:1, 10 MOhm, 1.5m
160 Memory Upgrade to 16Mpts/Ch, 32Mpts Max
320 Memory Upgrade to 32Mpts/Ch, 64Mpts Max
640 Memory Upgrade to 64Mpts/Ch, 128Mpts Max
A6J ANSI Z540 calibration
E2609B Rackmount Kit
E2621A Termination Adapter - Balanced 100/110/120-ohm
E2622A Termination Adapter - unbalanced 75 ohm
E2625A Communication Mask Test Kit
E2646A SQUiDD Test Fixture for USB 2.0 Testing
E2668A Connectivity kit - InfiniiMax for single-ended measurements
E2669A Connectivity kit, InfiniiMax - for differential measurements
E2675A Probe head - 6GHz InfiniiMax differential browser- wide span
E2682A VoiceControl SW for WinXP Infiniium Oscilloscopes
E2699A My Infiniium Integration Package Option
E5396A Probe, 17 channel single-ended soft touch connectorless, connects to 40-pin LA cable
E5396A-001 Retention Modules
MSO8000-002 EZJIT jitter analysis software package - installed
MSO8000-003 High-Speed SDA and Clock Recovery for 8000A Series Scopes - installed
MSO8000-006 Application Integration Package - My Infiniium installed
MSO8000-007 Low-Speed SDA - installed
MSO8000-008 CAN SDA - installed
MSO8000-009 InfiniiScan Event Identification Software for 8000 series - installed
MSO8000-010 Infiniium User-Definable Functions via MATLAB Gateway Application Software
MSO8000-017 Removable hard drive for Infiniium 8000 series oscilloscopes
MSO8000-018 Standard hard drive for Infiniium 8000 series oscilloscopes
MSO8000-019 External Touchscreen Monitor For Infiniium
MSO8000-020 DVD-RW drive
MSO8000-A6J ANSI Z540 calibration
MSO8004-040 Memory 4Mpts/Ch, 8Mpts Max
MSO8004-080 Memory Upgrade to 8Mpts/Ch, 16Mpts Max
MSO8004-160 Memory Upgrade to 16Mpts/Ch, 32Mpts Max
MSO8004-320 Memory Upgrade to 32Mpts/Ch, 64Mpts Max
MSO8004-640 Memory Upgrade to 64Mpts/Ch, 128Mpts Max
N5392A Ethernet Compliance Test Application
N5395B Ethernet Test Fixtures
N5395C Ethernet Test Fixtures
N5396A Jitter Test Cable for Ethernet Test Application
N5397A FPGA dynamic probe option for Xilinx with Infiniium Series MSOs
N5407A Infiniium 8000/54830 Series 4-channel Oscilloscope Memory Upgrade
N5414A InfiniiScan Event Identification Software for Infiniium Series oscilloscopes
N5416A USB 2.0 Compliance Test Software
N5430A Infiniium User Defined Function Application for Infiniium Series
N5433A FPGA dynamic probe option for Altera with Infiniium Series MSOs
R-50C-011-3 Agilent Calibration - 3 years
R-50C-011-5 Agilent Calibration - 5 years
R-50C-021-3 ANSI Z540-1-1994 Calibration - 3 years
R-50C-021-5 ANSI Z540-1-1994 Calibration - 5 years
R-51B-001-3C Return to Agilent Warranty - 3 years
R-51B-001-5C Return to Agilent Warranty - 5 years
R-51B-001-C Return to Agilent Warranty - 1 year
Specifications & Attributes (Oscilloscopes)
Form Factor
Plug-In ( /E5396A-001 )
Rackmount ( /E2609B )
Bandwidth
100 KHz ( /1146A )
50 MHz ( /1147A )
200 MHz ( /1153A )
250 MHz ( /10076B )
500 MHz ( /10073D )
1 Ghz
1.5 GHz ( /1130A /1156A )
6 GHz ( /E2675A )
Channels
4 Ch ( /N5407A )
4 analog + 16 digital Ch
17 Ch ( /E5396A )
Sample Rate
4 GSa/s
Type
Digital Storage (DSO)
Mixed Signal (MSO) ( /N5433A )

Request a Quote