Superior Validation, Debug, Analysis
The WaveRunner 6 Zi defines superiority in a test instrument. The powerful feature set includes a wide range of application packages, advanced triggering to isolate events, a user interface developed for quick and easy navigation, a wide range of probing options, and lightning-fast performance.
Most Comprehensive Serial Data Analysis
WaveRunner 6 Zi offers the most tools for serial data analysis. With over 17 trigger, decode, and compliance solutions, WaveRunner 6 Zi can address problems with unique, powerful views and automated tools. The unique measurement toolset, ProtoSync, combines the oscilloscope view with a simultaneous view of data link layer decodes on the same instrument.
Excellent Signal Fidelity
The WaveRunner 6 Zi oscilloscope family features a pristine signal path that offers unmatched signal fidelity with low noise. This performance is augmented by a huge offset and timebase delay adjustment to allow easy signal and amplifier performance assessment and zooming on vertical and horizontal signal characteristics.
A New Way to Navigate and View
The WavePilot control area provides convenient control of Cursors, Decode, WaveScan, History, LabNotebook, and Spectrum by their respective function buttons on the front panel.
The SuperKnob is a joystick-like knob in the center of the WavePilot control area used to easily navigate through tables, zoom and position waveforms, and quickly document and annotate your setups.
Simply slide the button on the left side of the display and rotate upwards 90º. The display will automatically change from landscape to portrait mode. The display will also pivot upwards and downwards to optimize viewing angle.
More Trigger Capability Isolates More Problems More Quickly
A powerful combination of high bandwidth edge and 10 different SMART triggers, four stage cascade triggering, measurement trigger, and TriggerScan are all standard and allow you to isolate the problem quickly and begin focus on the cause. The measurement trigger offers a powerful option to qualify a trigger event based on a qualified measurement with great resolution. A high-speed serial trigger enables triggering on up to 3 Gb/s serial patterns of up to 80-bits in length. A full range of serial triggers (I2C, SPI, UART, RS-232, Audio (I2S, LJ, RJ, TDM), CAN, LIN, FlexRay, MIL-STD-1553, SATA, PCIe, 8b/10b, USB2 and many others) are also available.
Rotating Display
The 12.1" high resolution WXGA wide screen is designed to provide the best view of any signal type on the display.
The widescreen is ideal for a variety of signals where long records are required and zooming or scrolling results in a large block of data.
Rotate the screen 90° degrees to optimize the display for viewing digital signals, jitter tracks, eye diagrams, and frequency plots. The screen image will adjust automatically when rotated. Tilt the display up or down in either orientation to minimize reflections or glare.
MS-250 | 250 MHz, 18 Channels, 1 GS/s, 10 Mpts/ch Mixed Signal Oscilloscope Option |
MS-500 | 500 MHz, 18 Channels, 2 GS/s, 50 Mpts/ch Mixed Signal Oscilloscope Option |
MS-500-36 | 250 MHz,36 Ch,1 GS/s,25 Mpts/ch (500MHz,18 Ch,2 GS/s,50 Mpts/ch Interleaved) Mixed Signal Option |
MSO-3M | 18 Pin 3M Interface cable MSO-3M (Mates with 3M part number 2520-6002) |
MSO-DLS-36 | 16" Digital Lead Set, D18-D35 |
MSO-MICTOR | 36 Channel Mictor Connector for MS Series (Includes 1 MSO-MICTOR-SHROUD) |
MSO-MICTOR-SHROUD | Shroud for MSO-MICTOR connector, Kit of 3 |
OC1021 | Oscilloscope Cart |
OC1024 | Oscilloscope Cart with Additional Shelf and Drawer |
PK400-1 | Large Gripper Probe Set for 0.10 inch (2.54mm) pin pitch. Includes 10 probes with color coded leads |
PK400-2 | Medium Gripper Probe Set for 0.04 inch (1.0mm) pin pitch. Includes 10 probes with color coded leads |
PK400-3 | Small Gripper Probe Set for 0.008 inch (0.2 mm) pin pitch. Includes 10 probes with color coded leads |
QPHY-BroadR-Reach | QualiPHY Enabled BroadR-Reach Compliance Software Option |
QPHY-DDR2 | QualiPHY Enabled DDR2 Compliance Software option |
QPHY-DDR3 | QualiPHY Enabled DDR3 Compliance Software option |
QPHY-ENET | QualiPHY Enabled Ethernet 10/100/1000BT Compliance Software Option |
QPHY-LPDDR2 | QualiPHY Enabled LPDDR2 Compliance Software option |
QPHY-MIPI-DPHY | QualiPHY Enabled MIPI DPHY Compliance Software Option |
QPHY-MOST150o | QualiPHY Enabled MOST150 oPHY Compliance Software Option. Requires options DFP2 and SDM or SDA2 |
QPHY-MOST50e | QualiPHY Enabled MOST50 ePHY Compliance Software Option. Requires options DFP2 and SDM or SDA2 |
QPHY-USB | QualiPHY Enabled USB 2.0 Compliance Software Option |
TF-ENET-B | 10/100/1000BaseT Ethernet Test Fixture |
TF-ET | Electrical Telecom Adapters |
TF-USB-B | USB 2.0 Compliance Test Fixture |
USB2-GPIB | External USB 2.0 to GPIB IEEE 488.2 adapter |
WR620Zi-M-64 | 64 Mpt/Ch (128 Mpt/Ch Interleaved) Standard Memory for WaveRunner 620Zi. Includes 4GB of RAM. |
WR620ZI-M-64-4X20GS | 64Mpt/Ch (128 Mpt/Ch Interleaved) Standard Memory, & 20GS/s (40GS/s Interleaved) Sampling Rate Option for 620Zi |
WR620Zi-S-32 | 32 Mpt/Ch (64 Mpt/Ch Interleaved) Standard Memory for WaveRunner 620Zi. Includes 4GB of RAM. |
WR620ZI-S-32-4X20GS | 32Mpt/Ch (64Mpt/Ch Interleaved) Standard Memory & 20GS/s (40GS/s Interleaved) Sampling Rate Option for 620Zi |
WR620Zi-STD-4x20GS | 20 GS/s (40 GS/s Interleaved) Sampling Rate Option for WaveRunner 620Zi |
WR6Zi-1553 TD | MIL-STD-1553 Trigger and decode option for WaveRunner 6Zi series |
WR6Zi-160GB-RHD | Removeable Hard Drive option for WaveRunner 6Zi series |
WR6Zi-160GB-RHD-02 | Additional 160 GB Hard Drive for use with RHD option. |
WR6Zi-500GB-HD | Upgrade from Standard Size Hard Drive to 500 GB Hard Drive |
WR6ZI-500GB-HD-02 | Additional 500GB Removeable Hard Drive for use with RHD option |
WR6Zi-500GB-RHD-02 | Additional 500 GB Hard Drive for use with RHD option. |
WR6Zi-80B-8b10b TD | 80-bit and 8b/10b Serial Trigger (up to 3.125 Gb/s). Also includes 8b/10b Decode |
WR6ZI-8CH-SYNCH | 8ch synch capability to combine 2 WR6Zi oscilloscopes |
WR6Zi-AORM | Advanced Optical Recording Measurement Package for WaveRunner Series |
WR6Zi-ARINCbus Dsymbolic | ARINC 429 Bus Symbolic Decode option for WaveRunner 6Zi series |
WR6Zi-AudioBus TD | AudioBus Trigger and Decode option for WaveRunner 6Zi series |
WR6Zi-AudioBus TDG | AudioBus trigger, decode, and graph option for WaveRunner 6Zi series |
WR6Zi-CANbus TD | CAN Bus Trigger & Decode Option for WaveRunner 6Zi series |
WR6Zi-CANbus TDM | CAN Bus Trigger, Decode & Measure/Graph Option for WaveRunner 6Zi series |
WR6Zi-CBL-DE-EMBED | Cable De-Embedding Option for WaveRunner 6Zi series |
WR6Zi-Cover | WaveRunner 6Zi Protective Front Cover |
WR6Zi-DDA | Disk drive analyzer software package for WaveRunner 6Zi series |
WR6Zi-DDM2 | Disk Drive Measurements Software Package for WaveRunner 6Zi Series |
WR6Zi-DFP2 | Digital Filter Software Package for WaveRunner 6Zi Series |
WR6Zi-DigRF3Gbus D | DigRF 3G Bus Decode option for WaveRunner 6Zi series |
WR6Zi-DigRFV4bus D | DigRF V4 Bus Decode option for WaveRunner 6Zi series |
WR6Zi-DPHYbus D | MIPI D-PHY CSI-2, DSI Bus Decode option for WaveRunner 6Zi series |
WR6Zi-DPHYbus DP | MIPI D-PHY CSI-2, DSI Bus Decode and Physical Layer test option for WaveRunner 6Zi series |
WR6Zi-EMB | Embedded bundle, Includes I2C TD, SPI TD, UART-RS232 TD |
WR6Zi-EMC | EMC Pulse Parameter Software Package for WaveRunner 6Zi Series |
WR6ZI-ENETBUS D | ENET Bus Decode Option |
WR6Zi-ET-PMT | Electrical Telecom Pulse Mask Test Package for WaveRunner 6Zi Series |
WR6Zi-ExtRef-IN/OUT | External Adaptor for Reference In and Out. To be applied at the Lbus connector |
WR6Zi-EyeDrII | Signal Integrity Toolkit - Channel & Fixture De-embedding/Emulation, Tx/Rx Equalization |
WR6Zi-FCbus D | FibreChannel decode annotation option for WaveRunner 6Zi series |
WR6Zi-FlexrayBus TD | FlexRay Bus Trigger & Decode Option for WaveRunner 6Zi series |
WR6Zi-FlexRayBus TDP | FlexRay Bus Trigger, Decode, and Physical Layer Test Option for WaveRunner Series Oscilloscopes |
WR6Zi-HARDCASE | WaveRunner 6Zi Hard Carrying Case |
WR6Zi-I2Cbus TD | I2C Bus Trigger & Decode Option for WaveRunner Series Oscilloscopes |
WR6Zi-JITKIT | Clock, clock-data Jitter Analysis and views of time, statistical, spectral, and jitter overlay |
WR6Zi-LINbus TD | LIN Bus Trigger & Decode Option for WaveRunner 6Zi series |
WR6Zi-MPHYbus D | MIPI M-PHY Bus Decode Option for WaveRunner 6Zi series |
WR6Zi-MPHYbus DP | MIPI M-PHY Bus Decode and Physical Layer test Option for WaveRunner 6Zi series |
WR6Zi-MSO-EMB | Embedded bundle, Includes MS-500-36 with I2C TD, SPI TD, UART TD |
WR6ZI-NRZBUS D | NRZ Bus Decode option |
WR6Zi-PCIebus TD | PCIe Gen 1 Trigger and Decode option for WaveRunner 6Zi series |
WR6Zi-PMA2 | PowerMeasure Analysis Software Package for WaveRunner Series |
WR6Zi-Pouch | WaveRunner 6Zi Accessory pouch.Includes mounting bracket. |
WR6ZI-PROTOBUS MAG | Serial Debug Toolkit - Measure Analyze Graph |
WR6Zi-ProtoSync | Decode Annotation and Protocol Analyzer Synchronization Option for WaveRunner 6Zi series. |
WR6Zi-PROTOSYNC-BT | Decode Annotation and Protocol Analyzer+Bit Tracer SW Synchronization Option for WaveRunner 6Zi |
WR6ZI-PWR | Power Analysis option |
WR6Zi-RACK | Rack-mount accessory for converting a WaveRunner 6Zi series oscilloscopeto an 8U rack-mounted package |
WR6Zi-SASbus D | SAS Decode annotation option for WaveRunner 6Zi series |
WR6Zi-SATAbus TD | SATA Trigger and Decode option for WaveRunner 6Zi series |
WR6ZI-SDAII | SDAII Software Option - Next Generation of Serial Data Analysis |
WR6Zi-SDM | Serial Data Mask Software Package for WaveRunner 6Zi Series |
WR6ZI-SENTBUS D | SENT Bus Decode Option |
WR6Zi-Softcase | WaveRunner 6Zi Soft Carrying Case |
WR6Zi-SPECTRUM | Spectrum Analyzer and Advanced FFT Option for WaveRunner 6Zi Series |
WR6Zi-SPIbus TD | SPI Bus Trigger & Decode Option for WaveRunner Series Oscilloscopes |
WR6Zi-UART-RS232bus TD | UART and RS232 Bus Trigger & Decode Option for WaveRunner 6Zi series |
WR6Zi-UPG-4GBRAM | Upgrade from 2 GB RAM to 4 GB RAM |
WR6ZI-USB2-HSICBUS D | USB 2.0 HSIC Decode Option |
WR6Zi-USB2bus TD | USB2 Trigger and Decode option for WaveRunner 6Zi series |
WR6Zi-VBA | Vehicle Bus Analyzer BundleIncludes CAN TDM, CAN Symbolic, FlexRay TDP, LIN TD and Protobus MAG. |
WR6Zi-XDEV | Developer's Tool Kit Option for WaveRunner Series |
Form Factor |
---|
Benchtop |
Bandwidth |
---|
2 GHz |
Channels |
---|
4CH |
Sample Rate |
---|
10GS/s |
Type |
---|