Tektronix P7313

DIFFERENTIAL PROBE, 12.5 GHZ
Contact us for pricing and availability.
Description
Tektronix has created a revolutionary Z-Active probe architecture that sets the industry benchmark for signal fidelity. Tektronix active probe architecture preserves high bandwidth while providing improved connectivity with low loading. The Z-Active architecture is a hybrid approach composed of a distributed attenuator topology feeding an active probe amplifier. The Z-Active probes use a tiny passive probe tip element that is separate from the amplifier, extending the usable reach of the probe. In traditional active probes, adding this much length can introduce signal fidelity problems. However, this architecture maintains high DC input resistance and presents a higher AC impedance than previous probe architectures. It accomplishes this while providing significant length between the probe body and the probe attachment point to the DUT. This architecture provides the best of both worlds: high DC impedance like existing active probes and the stable high frequency loading of Z0 probes. Features: Signal Fidelity
  • >12.5 GHz Bandwidth (P7313 only, Typical)
  • <40 ps Risetime 10% - 90% (P7313 only, Guaranteed)
  • <25 ps Risetime 20% - 80% (P7313 only, Typical)
  • Low Probe Loading
  • DC Input Resistance- 100 KO differential; 50 KO single-ended
  • AC loading- Zmin >200 O out to 10 GHz
  • Versatility- Solder down capability: Handheld probing with Variable spacing and compliance (>8 GHz); Fixtured probing
  • Interchangeable Tip-Clip™ assemblies:Connect to a variety of devices and Economical.
  • TekConnect® Interface
  • List of Options
    C3 CALIBRATION SERVICE 3 YRS. PROVIDES TRACEABLE OR FUNCTIONAL VERIFICATION EVENTS WHICHEVER ARE APPLICABLE TO THE PRODUCT. CALS ARE AT TEKTRONIX RECOMMENDED INTERVAL DURING THE COVERAGE PERIOD. CAL COVERAGE INCLUDES THE MANUFACTURERS CAL + 2
    C5 CALIBRATION SERVICE 5 YRS. PROVIDES TRACEABLE OR FUNCTIONAL VERIFICATION EVENTS WHICHEVER ARE APPLICABLE TO THE PRODUCT. CALS ARE AT TEKTRONIX RECOMMENDED INTERVAL DURING THE COVERAGE PERIOD. CAL COVERAGE INCLUDES THE MANUFACTURERS CAL + 4
    D3 CALIBRATION DATA REPORT 3 YEARS (WITH OPTION C3)
    D5 CALIBRATION DATA REPORT 5 YEARS (WITH OPTION C5)
    R3 REPAIR SERVICE 3 YEARS (INCLUDING WARRANTY)
    R3DW REPAIR SERVICE COVERAGE 3 YEARS (INCLUDES PRODUCT WARRANTY PERIOD) 3 YEAR PERIOD STARTS AT TIME OF CUSTOMER INSTRUMENT PURCHASE YEAR PERIOD STARTS AT TIME OF CUSTOMER INSTRUMENT PURCHASE
    R5 REPAIR SERVICE 5 YEARS (INCLUDING WARRANTY)
    R5DW REPAIR SERVICE COVERAGE 5 YEARS (INCLUDES PRODUCT WARRANTY PERIOD) 5 YEAR PERIOD STARTS AT TIME OF CUSTOMER INSTRUMENT PURCHASE