Description
Tektronix has created a revolutionary Z-Active probe architecture that sets the
industry benchmark for signal fidelity. Tektronix active probe architecture preserves
high bandwidth while providing improved connectivity with low loading. The Z-Active architecture is a hybrid approach composed of a distributed attenuator topology feeding an active probe amplifier.
The Z-Active probes use a tiny passive probe tip element that is separate from
the amplifier, extending the usable reach of the probe. In traditional active probes, adding this much length can introduce signal fidelity problems. However, this
architecture maintains high DC input resistance and presents a higher AC
impedance than previous probe architectures. It accomplishes this while providing
significant length between the probe body and the probe attachment point to the
DUT. This architecture provides the best of both worlds: high DC impedance like
existing active probes and the stable high frequency loading of Z0 probes.
Features:
Signal Fidelity
>12.5 GHz Bandwidth (P7313 only, Typical)
<40 ps Risetime 10% - 90% (P7313 only, Guaranteed)
<25 ps Risetime 20% - 80% (P7313 only, Typical)
Low Probe Loading
DC Input Resistance- 100 KO differential; 50 KO single-ended
AC loading- Zmin >200 O out to 10 GHz
Versatility- Solder down capability: Handheld probing with Variable spacing and compliance (>8 GHz); Fixtured probing
Interchangeable Tip-Clip™ assemblies:Connect to a variety of devices and
Economical.
TekConnect® Interface
List of Options
C3 |
CALIBRATION SERVICE 3 YRS. PROVIDES TRACEABLE OR FUNCTIONAL VERIFICATION EVENTS WHICHEVER ARE APPLICABLE TO THE PRODUCT. CALS ARE AT TEKTRONIX RECOMMENDED INTERVAL DURING THE COVERAGE PERIOD. CAL COVERAGE INCLUDES THE MANUFACTURERS CAL + 2 |
C5 |
CALIBRATION SERVICE 5 YRS. PROVIDES TRACEABLE OR FUNCTIONAL VERIFICATION EVENTS WHICHEVER ARE APPLICABLE TO THE PRODUCT. CALS ARE AT TEKTRONIX RECOMMENDED INTERVAL DURING THE COVERAGE PERIOD. CAL COVERAGE INCLUDES THE MANUFACTURERS CAL + 4 |
D3 |
CALIBRATION DATA REPORT 3 YEARS (WITH OPTION C3) |
D5 |
CALIBRATION DATA REPORT 5 YEARS (WITH OPTION C5) |
R3 |
REPAIR SERVICE 3 YEARS (INCLUDING WARRANTY) |
R3DW |
REPAIR SERVICE COVERAGE 3 YEARS (INCLUDES PRODUCT WARRANTY PERIOD) 3 YEAR PERIOD STARTS AT TIME OF CUSTOMER INSTRUMENT PURCHASE YEAR PERIOD STARTS AT TIME OF CUSTOMER INSTRUMENT PURCHASE |
R5 |
REPAIR SERVICE 5 YEARS (INCLUDING WARRANTY) |
R5DW |
REPAIR SERVICE COVERAGE 5 YEARS (INCLUDES PRODUCT WARRANTY PERIOD) 5 YEAR PERIOD STARTS AT TIME OF CUSTOMER INSTRUMENT PURCHASE |