Rohde and Schwarz FSU26

RF Spectrum Analyzer, 20 Hz to 26.5 GHz
Contact us for pricing and availability.
Description
The R&S FSU spectrum analyzers are performance leaders in dynamic range, phase noise, level accuracy and resolution bandwidth- all factors that are essential for the user's ability to design, characterize, and manufacture next generation wireless elements. Features
  • Frequency Range- 20 Hz to 26.5 GHz
  • DANL- -158dBm (1 Hz RBW)
  • Phase Noise (Typ.)- -133 dBc @ 10 KHz offset (1 Hz RBW)
  • TOI (Typ.) +25 dBm
  • Resolution Bandwidth- 1 Hz to 50 MHz
  • DANL with Preamplifier option B24: typ. -168 dBm (1Hz RBW) @ 20 GHz
  • Fast ACP in time domain
  • Up to 70 measurments per second(including trace transfer via GPIB)
  • Measurement routines for TOI, MC ACP(R), OBW, CCDF, APD, etc. as standard.
  • Application firmware available for GSM/EDGE, Bluetooth, WCDMA/ HSPDA/ TD-SCDMA, CDMA-2000/ 1xEV-DV/ 1xEV-D0, etc.
List of Options
1R Rack mount Adapter ZZA-94
B04 OCXO 10MHZ FOR FSU AGING/YEAR
B10 External generator control for FSP, FSU, FSG, FSQ, ESU, ESCI, ESPI and for retrofit of
B12 Output attenuator for tracking generator for FSU, FSQ
B16 LAN interface
B18 Removable Hard Disk (not retrofittable)
B19 B18,vaSecond Hard Disk for FSU-B18 (for FSU-riant 1303.0400.02)
B20 Extended environment specification. Random vibr. 1.9G RMS, 0-55°C (not retrofittable)
B21 LO/ZF connections for external mixers (for FSQ26, FSQ40,FSU26, FSU43, FSU46, FSU50)
B23 Preamplifier 20 dB to FSU26, 3.6 - 26.5 GHz not retrofittable
B24 Preamplifier 30dB, 100 kHz to 50GHz (for FSMR26/43/50, FSQ26/40, FSU26/43/46/50;
B25 Electronic attenuator 0 to 30 dB, Preamplifier 20 dB, 10MHz - 3.6 GHz for FSU, FSQ
B27 FM output, 10 MHz bandwidth
B28 Trigger port for FSP,FSQ,FSU; for indication of trigger conditions
B4 OCXO 10 MHz aging/year: 0.35*10E-7 for FSU, FSQ, FSMR
B5 Output for low phase noise 640MHz reference signal for FSU3, FSU8, FSQ3 und FSQ8
B73 Vector signal analysis for FSU demodulation bandwidth 8 MHz (FSU), broadband demodulation hardware included
B87 Extended linearity specification for specific channel filters
B88 RF hardware option 1 FSU26
B9 Tracking generator for FSU and FSQ, 100 kHz - 3.6 GHz
C3 Three years of depot calibration coverage based on the R&S recommended calibration interval - includes test data. The first calibration is included with product delivery with 2 additional depot calibration(s).
C5 Five years of calibration coverage based on the R&S recommended calibration interval - includes test data. The first calibration is included with product delivery with 4 additional depot calibration(s).
DCV-2 Documentation of calibration values
DCV-ZP Printout of DCV (additional, in combination with DCV-Option only)
DKD FSU26 DKD (ISO17025) calibration incl. ISO 9000 calibration (order only with device)
FS-B33 USB mass memory write protection, disables writing to USB memory sticks (ex factory only)
FS-K10 GSM/EDGE/EDGE Evolution Measurement Appl (for FSG/FSQ/FSU)
FS-K110 Analysis of TETRA II / TEDS signals (for FSQ, FSU with option FSU-B73)
FS-K15 VOR/ILS measurements for FSMR
FS-K30 Application firmware for noise figure and gain measurements for FSMR, FSP, FSQ, FSU
FS-K40 Application firmware for phase noise measurements for FSMR, FSP, FSQ, FSU
FS-K5 Application firmware GSM/EDGE tests for FSP, FSU, FSQ
FS-K5U Upgrade of FS-K5 to FS-K10, GSM/EDGE/EDGE Evolution Measurement Appl (for FSG, FSQ, FSU)
FS-K7 FM demodulator, allows measurement of FM specific parameters (for FMU, FSP, FSU)
FS-K72 Application firmware 3GPP-FDD BTS transmitter test for FSMR, FSP, FSU, FSQ
FS-K73 Application firmware 3GPP-FDD UE transmitter test for FSMR, FSP, FSU, FSQ
FS-K73+ 3GPP HSPA+ UE transmitter test, application firmware (for FSMR, FSP, FSQ, FSU, FSUP,
FS-K74 3GPP HSDPA base station test application firmware for FSMR, FSU, FSP, FSQ
FS-K74+ 3GPP HSPA plus, base station test. Application firmware (for FSP, FSQ, FSU, FSG;
FS-K76 3GPP TD-SCDMA base station test; application firmware for FSMR, FSP, FSQ, FSU
FS-K77 3GPP TD-SCDMA mobile station test; application firmware for FSMR, FSP, FSQ, FSU
FS-K8 Application firmware for Bluetooth measurement on FSP, FSU and FSQ
FS-K82 CDMA2000/1xEV-DV base station test application firmware for FSMR, FSP, FSU, FSQ
FS-K83 CDMA2000/1xEV-DV mobile station application firmware for FSMR, FSP, FSQ, FSU
FS-K84 1xEV-DO base station test application firmware for FSMR, FSU, FSP, FSQ
FS-K85 1xEV-DO mobile station test application firmware for FSMR, FSP, FSQ, FSU
FS-K9 Measurements with NRP power sensors NRPZ11/Z21/Z22/Z23/Z24/Z51/Z55/Z91 requires NRP-Z3 or NRP-Z4
FSP-B10 External generator control for FSP, FSU, FSG, FSQ, ESU, ESCI, ESPI and for retrofit of
FSP-B28 Trigger port for FSP,FSQ,FSU; for indication of trigger conditions
K3 Noise Figure Measurement Software
K30 Application firmware for noise figure and gain measurements for FSMR, FSP, FSQ, FSU
K4 PHASE NOISE MEASURMNT SW
K40 Application firmware for phase noise measurements for FSMR, FSP, FSQ, FSU
K5 Application firmware GSM/EDGE tests for FSP, FSU, FSQ
K7 FM demodulator, allows measurement of FM specific parameters (for FMU, FSP, FSU)
K70 Vector Signal Analyzer, Reqs Opt B73
K72 Application firmware 3GPP-FDD BTS transmitter test for FSMR, FSP, FSU, FSQ
K73 Application firmware 3GPP-FDD UE transmitter test for FSMR, FSP, FSU, FSQ
K74 3GPP HSDPA base station test application firmware for FSMR, FSU, FSP, FSQ
K76 3GPP TD-SCDMA base station test; application firmware for FSMR, FSP, FSQ, FSU
K77 3GPP TD-SCDMA mobile station test; application firmware for FSMR, FSP, FSQ, FSU
K8 Application firmware for Bluetooth measurement on FSP, FSU and FSQ
K82 CDMA2000/1xEV-DV base station test application firmware for FSMR, FSP, FSU, FSQ
K83 CDMA2000/1xEV-DV mobile station application firmware for FSMR, FSP, FSQ, FSU
K84 1xEV-DO base station test application firmware for FSMR, FSU, FSP, FSQ
K85 1xEV-DO mobile station test application firmware for FSMR, FSP, FSQ, FSU
K9 Measurements with NRP power sensors NRP-Z11/Z21/Z22/Z23/Z24/Z51/Z55/Z91 requires NRP-Z3 or NRP-Z4
R3 Three years of depot repair coverage, including re-calibration if necessary to complete the repair. First year of repair coverage is provided by the 12-month new product warranty.
R5 Five years of depot repair coverage, including re-calibration if necessary to complete the repair. First year of repair coverage is provided by the 12-month new product warranty.
U2
ZZA-411 19" adapter, 4 HU, 1/1 for BW2000 cabinets
Specifications & Attributes (Spectrum Analyzers)
Form Factor
Rackmount ( /ZZA-411 )
Application Software
Bluetooth ( /K8 )
CDMA2000 ( /K82 )
CDMAONE ( /K82 )
GSM with Edge ( /K5 )
HSDPA ( /K74 )
Noise Figure ( /K3 )
Phase Noise ( /K4 )
TD-SCDMA ( /K77 )
Average Noise Level
-158 dBm
Frequency
10 MHz ( /B27 /B4 )
640 MHz ( /B5 )
100 KHz - 3.6 GHz ( /B9 )
10 MHz - 3.6 GHz ( /B25 )
20 Hz - 26.5 GHz

Request a Quote