Description

The R&S FSU67 is the first spectrum analyzer with a direct frequency range to 67 GHz and fundamental mixing. It allows measurements to 67 GHz without using cumbersome setups with external mixers.

  • Simplified test set-ups with just one connection from 20 Hz to 67 GHz
  • Full span sweep of 67 GHz
  • Unambiguous frequency indication without the image response and multiple responses known from external harmonic mixers
  • Wider level range with a much higher allowable reference level than with harmonic mixers
  • Good level accuracy to 67 GHz
  • Low noise floor: -152 dBm (1 Hz) at 2 GHz, -130 dBm (1 Hz) at 65 GHz
  • Wide range of resolution bandwidth: 1 Hz to 50 MHz
  • Versatile filter characteristics: Gaussian, channel filters, FFT, 6-dB EMI filters
  • Full range of detectors including RMS, quasipeak
  • Comprehensive power measurement functions (CP, ACP, time domain power)
  • NRP power heads can be connected directly (Option FS-K9 and NRP-Z6 required)
  • Harmonic distortion and spurious emissions measurement function
  • High display linearity < 0.1 dB
  • Phase noise and noise figure application firmware
  • External generator control for use of an external microwave generator as tracking generator for scalar network measurements
List of Options
B12 Output attenuator for tracking generator for FSU, FSQ
B18 Removable Hard Disk (not retrofittable)
B19 Second Hard Disk for FSU-B18 (for FSU-B18,variant 1303.0400.02)
B20 Extended environment specification. Random vibr. 1.9G RMS, 0-55°C (not retrofittable)
B21 LO/ZF connections for external mixers (for FSQ26, FSQ40,FSU26, FSU43, FSU46, FSU50)
B24 Preamplifier 30dB, 100 kHz to 50GHz (for FSMR26/43/50, FSQ26/40, FSU26/43/46/50;
B25 Electronic attenuator 0 to 30 dB, Preamplifier 20 dB, 10MHz - 3.6 GHz for FSU, FSQ
B27 FM output, 10 MHz bandwidth
B4 OCXO 10 MHz aging/year: 0.35*10E-7 for FSU, FSQ, FSMR
B5 Output for low phase noise 640MHz reference signal for FSU3, FSU8, FSQ3 und FSQ8
B73 Vector signal analysis for FSU demodulation bandwidth 8 MHz (FSU), broadband demodulation hardware included
B9 Tracking generator for FSU and FSQ, 100 kHz - 3.6 GHz
C3 THREE YRS OF DEPOT FACTORY STANDARD CALIBRATION BASED ON THE R&S RECOMMENDED CALIBRATION INTERVAL - INCLUDES TEST DATA. THE FIRST CALIBRATION IS INCLUDED WITH PRODUCT DELIVERY WITH 2 ADDITIONAL DEPOT CALIBRATION(S).
C5 THREE YRS OF DEPOT FACTORY STANDARD CALIBRATION BASED ON THE R&S RECOMMENDED CALIBRATION INTERVAL - INCLUDES TEST DATA. THE FIRST CALIBRATION IS INCLUDED WITH PRODUCT DELIVERY WITH 2 ADDITIONAL DEPOT CALIBRATION(S).
DCV-2 Documentation of calibration values
DCV-ZP Printout of DCV (additional, in combination with DCV-Option only)
DKD FSU67 DKD (ISO17025) calibration incl. ISO 9000 calibration (order only with device)
FS-K10 GSM/EDGE/EDGE Evolution Measurement Appl (for FSG/FSQ/FSU)
FS-K15 VOR/ILS measurements for FSMR
FS-K30 Application firmware for noise figure and gain measurements for FSMR, FSP, FSQ, FSU
FS-K40 Application firmware for phase noise measurements for FSMR, FSP, FSQ, FSU
FS-K5 Application firmware GSM/EDGE tests for FSP, FSU, FSQ
FS-K5U Upgrade of FS-K5 to FS-K10, GSM/EDGE/EDGE Evolution Measurement Appl (for FSG, FSQ, FSU)
FS-K7 FM demodulator, allows measurement of FM specific parameters (for FMU, FSP, FSU)
FS-K72 Application firmware 3GPP-FDD BTS transmitter test for FSMR, FSP, FSU, FSQ
FS-K73 Application firmware 3GPP-FDD UE transmitter test for FSMR, FSP, FSU, FSQ
FS-K73+ 3GPP HSPA+ UE transmitter test, application firmware (for FSMR, FSP, FSQ, FSU, FSUP,
FS-K74 3GPP HSDPA base station test application firmware for FSMR, FSU, FSP, FSQ
FS-K74+ 3GPP HSPA plus, base station test. Application firmware (for FSP, FSQ, FSU, FSG;
FS-K76 3GPP TD-SCDMA base station test; application firmware for FSMR, FSP, FSQ, FSU
FS-K77 3GPP TD-SCDMA mobile station test; application firmware for FSMR, FSP, FSQ, FSU
FS-K8 Application firmware for Bluetooth measurement on FSP, FSU and FSQ
FS-K82 CDMA2000/1xEV-DV base station test application firmware for FSMR, FSP, FSU, FSQ
FS-K83 CDMA2000/1xEV-DV mobile station application firmware for FSMR, FSP, FSQ, FSU
FS-K84 1xEV-DO base station test application firmware for FSMR, FSU, FSP, FSQ
FS-K85 1xEV-DO mobile station test application firmware for FSMR, FSP, FSQ, FSU
FS-K9 Measurements with NRP power sensors NRP-Z11/Z21/Z22/Z23/Z24/Z51/Z55/Z91 requires NRP-Z3 or NRP-Z4
FSP-B10 External generator control for retrofit of FSP, FSU, FSQ, ESPI, ESCI
FSP-B28 Trigger port for FSP,FSQ,FSU; for indication of trigger conditions
R3 THREE YEARS OF DEPOT REPAIR COVERAGE, INCLUDING FACTORY STANDARD RE-CALIBRATION IF NECESSARY TO COMPLETE THE REPAIR. FIRST YEAR OF REPAIR COVERAGE IS PROVIDED BY THE 12-MONTH NEW PRODUCT WARRANTY.
R5 FIVE YEARS OF DEPOT REPAIR COVERAGE, INCLUDING FACTORY STANDARD RE-CALIBRATION IF NECESSARY TO COMPLETE THE REPAIR. FIRST YEAR OF REPAIR COVERAGE IS PROVIDED BY THE 12-MONTH NEW PRODUCT WARRANTY.
ZZA-411 19" adapter, 4 HU, 1/1 for BW2000 cabinets
Specifications & Attributes (Spectrum Analyzers)
Application Software
Bluetooth ( /FS-K8 )
CDMA2000 ( /FS-K82 /FS-K83 )
GSM with Edge ( /FS-K10 /FS-K5 /FS-K5U )
HSDPA ( /FS-K74 )
Noise Figure ( /FS-K30 )
Phase Noise ( /FS-K40 )
TD-SCDMA ( /FS-K76 /FS-K77 )
Average Noise Level
-152 dBm - -130 dBm
Frequency
8 MHz ( /B73 )
10 MHz ( /B27 /B4 )
640 MHz ( /B5 )
100 KHz - 3.6 GHz ( /B9 )
10 MHz - 3.6 GHz ( /B25 )
100 KHz - 50 GHz ( /B24 )
20 Hz - 67 GHz